- ページ 13

リピーター DIS Repeater RP 6004のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。DIS Repeater RP 6004 14 ページ。 Repeater for dcs 6000

Danish Interpretation Systems

Technical appendix

Cabling

CAT5
The DCS 6000 system uses CAT5, CAT5e or
CAT6 FTP or STP cables with screened RJ45
connectors.
It is important to use only FTP or STP
(screened) cables and screened RJ45 connectors
and not UTP cable, which is unscreened.
EIA 568-B wiring shall be used. How to wire a
CAT5 (EIA 568-B) Cable :
Pin Function
Connector
1
In-going +
ORG/WHT
2
In-going -
ORG
3
+48V
GRN/WHT
4
0V
BLU
5
0V
BLU/WHT
6
+48V
GRN
7
Outgoing -
BRN/WHT
8
Outgoing +
BRN
Note. If other colour codes are used then the four
pairs are connected as follows:
Pair 1:
Pin 1 & 2

Technical specifications

General
Power consumption ....................................................max. 10W
Temperature to guarantee specified performance
............................. 5 Deg C. to 40 Deg C. (35 to 80% humidity)
Storage temperature
..........................-20 Deg C. to 60 Deg C. (10 to 80% humidity)
Weight................................................................................... 1 kg
#1
Connector #2
ORG/WHT
ORG
GRN/WHT
BLU
BLU/WHT
GRN
BRN/WHT
BRN
Manual 01 18 04466
Pair 2:
Pin 3 & 6
Pair 3:
Pin 4 & 5
Pair 4:
Pin 7 & 8
The phase of the pairs must be correct and the
wiring spec. as stated in CAT5 (EIA 568-B) have to
be followed.
Note: CAT6 cables can normally only be
terminated in sockets (female) and not in cable
plugs. CAT6 should thus only be used for long
cable draws terminating in wall outlets or patch
panels.

Accessories (not supplied)

Cat 5e Connection Cables (AWG24)
EC 6000-..5 Connection Cable 0,5 m ......................10 03 12500
EC 6000-01 Connection Cable 1 m .........................10 03 13101
EC 6000-02 Connection Cable 2 m .........................10 03 13201
EC 6000-05 Connection Cable 5 m .........................10 03 13501
EC 6000-10 Connection Cable 10 m .......................10 03 14102
EC 6000-20 Connection Cable 20 m .......................10 03 14202
EC 6000-50 Connection Cable 50 m .......................10 03 14502
Set of 1HU - 19" Brackets...........................................................
Dimensions (W x H x D) ..............................264 x 42 x 128 mm
Dimensions with 19" brackets...................482,6 x 44 x 128 mm
Connectors
DCS-LAN loop through ........................................2 pieces RJ45
DCS-LAN repeated output ....................................4 pieces RJ45
Specifications are subject to change without notice.
User Manual
13