- ページ 2

ヒートポンプ Armstrong Air Conditioning 4HP14のPDF インストール&スタートアップ手順をオンラインで閲覧またはダウンロードできます。Armstrong Air Conditioning 4HP14 17 ページ。 Split system

NOTE TO INSTALLING DEALER
These instructions and warranty are to be given to the owner
or displayed near the indoor air handler unit.
WARNING
This product and/or the indoor unit that is matched with
may contain fiberglass wool.
Disturbing the insulation during installation,
maintenance, or repair will expose you to fiberglass wool
dust. (Fiberglass wool is known to the State of California
to cause cancer.)
Fiberglass wool may also cause respiratory, skin, and
eye irritation.
To reduce exposure to this substance or for further
information, consult material safety data sheets
available from your distributor.
WARNING
Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF position.
There may be more than 1 disconnect switch. Lock
out and tag switch with a suitable warning label.
Electrical shock can cause personal injury or death.

Safety Precautions

Follow all safety codes. Wear safety glasses and work
gloves. Use quenching cloth for brazing operations. Have
fire extinguisher available. Read these instructions
thoroughly and follow all warning or cautions attached to
the unit.
1. Always wear proper personal protection equipment.
2. Always disconnect electrical power before removing
panel or servicing equipment.
3. Keep hands and clothing away from moving parts.
4. Handle refrigerant with caution, refer to proper
MSDS from refrigerant supplier.
5. Use care when lifting, avoid contact with sharp
edges.
Page 2 of 17
gas to LP gas.
Issue 0946
UNIT LOCATION & INSTALLATION
NOTE: In some cases noise in the living area has been
traced to gas pulsations from improper installation of
equipment.
1. Locate unit away form windows, patios, decks, etc.
where unit operation sounds may disturb customer.
2. Ensure that vapor and liquid tube diameters are
appropriate to capacity of unit.
3. Run refrigerant tubes as directly as possible by avoiding
unnecessary turns and bends.
4. Leave some slack between structure and unit to absorb
vibration.
5. When passing refrigerant tubes through the wall, seal
opening with RTV or other silicon-based caulk.
6. Avoid direct tubing contact with water pipes, duct work,
floor joists, wall studs, floors, walls, and any structure.
7. Do not suspend refrigerant tubing from joists and studs
with a rigid wire or strap which comes in direct contact with
tubing.
8. Ensure that tubing insulation is pliable and completely
surrounds vapor tube.
When outdoor unit is connected to factory-approved
indoor unit, outdoor unit contains system refrigerant charge
for operation with indoor unit of the same size when
connected by 15 ft. of field-supplied tubing. For proper unit
operation, check refrigerant charge using charging
information located on control box cover.
IMPORTANT:
Maximum liquid-line size is 3/8 in. O.D.
for all residential applications including
long lines.
Outdoor Section
Zoning ordinances may govern the minimum distance
the condensing unit can be installed from the property line.
Install on a Solid, Level Mounting Pad
The outdoor section is to be installed on a solid
foundation. This foundation should extend a minimum of
2" (inches) beyond the sides of the outdoor section. To
reduce the possibility of noise transmission, the foundation
slab should NOT be in contact with or be an integral part of
the building foundation.
506318-01