- ページ 2

懐中電灯 Armytek Partner Pro C1のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Armytek Partner Pro C1 2 ページ。

Armytek Partner Pro C1 ユーザーマニュアル
Set description
2
1
3
Partner
Items included in the package:
1 - Flashlight
5 - Lanyard
2 - Clip
6 - 2 spare O-rings
3 - Spare rubber button
7 - User manual
4 - Holster
Depending on the model, your flashlight can inconsiderably differ from the pictures in the manual.
ь
The producer reserves the right to change the package at his own discretion without modifying this manual.
ь
Initial Service
1.
2.
To set/replace batteries:
1. Unscrew the tailcap.
2. Place the batteries with the positive contact (+) facing the head of the flashlight.
3. Adjust the tailcap and tighten it as far as it can go.
We recommend NOT to leave power sources inside the flashlight for a long storage period, as batteries (especially, non-rechargeable) can leak
for various reasons and damage the inner parts of the flashlight. If you want to keep your flashlight in a stand-by state with batteries in, use new
and quality batteries, store the flashlight in acceptable for batteries operational temperature and revise the batteries' state at least once a
month. If you have noticed any signs of batteries' defects, withdraw them from the flashlight and take out of operation. It is also recommended
to replace discharged batteries with new ones before the storage as the chance of leakage is higher with discharged batteries.
5
x2
6
4
7
3.
Operation
The flashlights has 2 types of operation:
General. The flashlight is switched on/off permanently.
Tactical. The light turns on for the time the button is being pressed. It will switch on in the last memorized mode (except for the Special
modes). This type of operation is useful for short-time lighting and setting signals.
General
Tighten up
Click x1
OFF
гд
ON
Cycling through modes
Click x1
Firefly
Maximum
Main1
Main3
Main2
Strobe
Press & Hold
Click
Strobe в Last used mode
ON
or
гд
Press & Hold
Strobe
Strobe в Firefly
Tactical
Half Press & Hold (no click)
Release
1/2
ǁ
OFF
ON
State Indication
Battery level
Switching State Indication ON/OFF
< 100%
1
+
2
< 50%
5sec
Press & Hold
Low Battery Indication
High Temperature Indication
Warning
Critical
Warning
Critical
1sec
0.5sec
2sec
1sec
< 25%
< 5%
WARM
HOT
< 10%
HOT
вFirefly1
в65% of output
вOFF
вFirefly2
Automemorizing. After switching off the last used Mode is memorized for quick 1-click access at next switching on.
Lock-out function. Unscrew the tailcap to 1/4 for the protection from accidental switching on.
General:
1. First full click of the tailcap button turns the light on at the last used
mode.
2. Second full click turns it off.
Cycling through modes:
1. To switch the mode click the side button.
2. The modes switch cyclically: Firefly - Main1 - Main2 - Main3 -
Maximum.
Strobe:
1. When the flashlight is ON (at any mode) press and hold the side
button to turn on Strobe.
2. To switch to the last used mode click the side button once.
3. To switch to the Firefly mode press and hold the side button.
Tactical (only by tailcap button):
1. For tactical activation use half-pressing of the tailcap button (no
click!).
2. The light remains on while you half press the button.
Multicolor State Indication. Shows the battery level by short flashes
every 5 seconds. Only C2 Pro has State Indication in Firefly modes.
Switching Multicolor State Indication ON/OFF (C2 Pro only). It is
switched off by default in Firefly modes. To turn on and off: unscrew the
tailcap to 1/4 (the tailcap switch must be in ON state), press the side
button and holding the button pressed - tighten the tailcap and then
unscrew it again. The settings will be memorized even when battery is
changed.Warning Indication. In ON-state shows the battery level and
the temperature inside the flashlight.
Low battery level. When it is <25%, the color LED shows the warning
level once a second and the main LED flashes 2 times once a minute.
Critical level <5% is color indicated twice a second and light output
decreases to Firefly1 and then switched off.
High temperature. When it increases to the warning level, the color LED
flashes 3 times once in 2 seconds. At critical level the color LED flashes
3 times once a second, the main LED flashes 4 times once and the light
output decreases by 35%. In case the temperature doesn't fall the light
output decreases to Firefly2. At normal temperature the brightness
increases to usual level.
C2 Pro only: With ambient temperature +25°C the flashlight delivers
light in Maximum mode for about 6-10 minutes before the
temperature reaches critical level and brightness decreases. After
cooling-down (provided that battery voltage is sufficient) the
brightness increases to the Maximum mode again. This stepping
goes cyclically to maintain the user's safety and the flashlight's
functionality. In conditions of good air-cooling the flashlight delivers
constant light even in Maximum mode. There are no preset timers
for stepping, but real-time active temperature measurements.