- ページ 3

池のポンプ Blagdon Hydratech Torrent 5500のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Blagdon Hydratech Torrent 5500 6 ページ。

2. GETTING TO KNOW YOUR HYDRATECH TORRENT PUMP

HYDRATECH TORRENT 5500/8000E/10500E
No.
1
2
3
4
5
Pump performance/flow chart
Model
900 cm
850 cm
6
800 cm
750 cm
700 cm
650 cm
600 cm
550 cm
7
500 cm
450 cm
400 cm
8
350 cm
300 cm
250 cm
9
200 cm
150 cm
10
100 cm
50 cm
00 cm
Model
Name of Part
Code
1.
Multi Hosetail
1041171
2.
Adaptor
1041188
3.
Pump Body
-
4.
Shaft Locator
1041195
5.
Impeller Assembly
5500
1041201
8000E
1041256
10500E
1041287
6.
Shaft including Locator
5500/8000E
1041218
10500E
1041294
7.
Impeller Base Plate
O-Ring
1041225
8.
Impeller Base Plate
5500
1041232
8000E
1041270
10500E
1041300
9.
Impeller Base Plate
Locating Screws
1041263
10.
Pond Floor Intake
1041249
5500
8000E
10500E
450
1100
1750
2400
3050
3850
4650
1100
5375
1750
6100
2700
6650
3450
7200
900
4200
7725
1600
5100
8250
2300
5600
8775
2900
6300
9300
3450
6750
9625
4250
7250
9950
4800
7600
10225
5450
8000
10500
5500
8000E
10500E
HYDRATECH TORRENT FLOW RATE IN LITRES/HOUR
3. GETTING TO KNOW YOUR HYDRATECH TORRENT PUMP
Technical Specification and Performance
3000
4000
HYDRATECH TORRENT
Cable
10m
10m
Voltage
230V
230V
Hertz
50Hz
50Hz
Watts
50W
69W
CC _
Safety Rating
IP68
IP68
Maximum Flow
3000ltr/hr
3875ltr/hr
660gal/hr
852gal/hr
Maximum Lift
2.85m/9'3" 3.1m/10'1" 4m/13'1"
Duplex Magflow Motor / Self-cleaning
The Hydratech Torrent pump has a unique impeller design. The self-cleaning
action impeller prevents large waste from blocking the impeller.
If an object becomes trapped the blades reverse direction cutting through soft
waste and throwing stones clear.
Duplex Magflow Electronic / Soft Start / Self-cleaning
Soft Start allows the motor to slowly accelerate when switched on and during
the self-cleaning cycle, increasing the life span of all moving parts.
Normal Flow
Blocked
IMPORTANT:
The duplex action of the impeller will cause noise and
intermittent flow on start up and during self-cleaning. THIS IS NOT A
FAULT. Electronic models incorporate a soft start cleaning cycle which
repeats every 30 seconds to clear the pump when blocked. Turning the
pump off and on may also restart the pump. If the self-cleaning action
cannot clear the blockage it will be necessary to manually remove the
object from the impeller following the maintenance instructions in section 6.
5500
8000E
10500E
10m
10m
10m
230V
230V
230V
50Hz
50Hz
50Hz
135W
140W
263W
CC _
CC _
CC _
CC _
IP68
IP68
IP68
5450ltr/hr
8000ltr/hr
10500ltr/hr
1200gal/hr
1760gal/hr
2310gal/hr
6m/19'6"
9.5m/31'2"
Reverse