- ページ 9
カメラアクセサリー DISCOVER 14-24-2800のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。DISCOVER 14-24-2800 14 ページ。 For motive power applications
DISCOVER 14-24-2800 にも: 取扱説明書 (13 ページ)
Spikes are fast, short duration electrical transients in voltage (voltage spikes), current (current spikes), or transferred energy
(energy spikes) in an electrical circuit. Voltage spikes usually happen when the AC/DC adapter is plugged in, or charge current is
cut off quickly. Multi voltage chargers are constructed using transformers that may be capable of producing spikes that exceed
the maximum ratings of the Discover AES Battery. You must ensure that the charger being supplied:
• Meets the recommended charge curve
• Incapable of exceeding Discover's maximum terminal voltages
6.3 Open Loop Charge Curve
1.
Charge at constant current to 3.4 V per cell module (Bulk).
2.
Maintain constant voltage 3.4 V per cell module (Absorption).
3.
Terminate when charge current drops below 2A.
4.
Optional Float at 3.35V per cell module (Float).
Model
14-24-2800
12-36-6700
12-48-6650
9
NOT ALL CHARGERS ARE CAPABLE OF CHARGING LITHIUM BATTERIES
CONFIRM that your chosen charger is incapable of producing transient
spikes that exceed the published terminal voltage limits for the battery.
Bulk
I
1
Max
100%
80%
I
1
Rec
60%
40%
20%
Voltage - U
Do not charge battery higher than 3.4 V per cell module.
Recommended charge current is 0.5C.
Cell Modules
in Series
8S
110 Adc maximum
12S
150 Adc maximum
16S
130 Adc maximum
▲ CAUTION!
Absorption
U
1
Current - I
▲ CAUTION!
▲ NOTE!
Absorption
Bulk Current
Voltage
27.2 V
40.8 V
54.4 V
3.6
3.4
3.2
3
2.8
Termination
Charge Current
I2 ≤ 2 A
discoverbattery.com