Commissioning

To commission the air water separator VT2 proceed as follows:
1.
Connect the water separator VT2 electrically, s. page 7.
2.
Ensure that the waste water hose has been connected to the threaded connector
for waste water.
3.
Ensure that the air tube has been connected to the connector for the compressor
(s. page 5, Fig. 1, item 2) and to the air intake pipe on the compressor.
4.
Ensure that the compressor (soundbox VP2/VP3/ VP6) has been connected to the
appliance socket of the water separator VT2.
5.
Switch on the water separator VT2 via the "On / Off" switch (s. page 5, Fig. 1, item 1).
The following indication appears in the display:
Serial number of electronics system
After booting the following indication appears in the display:
Pump cycle volume in liters
OPERATION AND OPERATOR CONTROL
Total delivery volume of the pump
(value not erasable)
Delivery volume since last
switching-on of device
Pump switches on and runs as long
as the key is kept pressed,
indicator flashes
Software version
Time in h
PG = 54621.0l
active
VT2
V 2.0
SN
123456
00:00 h
0 l
435.8l
Pump
Page 9 of 15