4. APPLICATIONS & SET-UP APPLICATIONS
Diagram 3 - Location of Dipswitch Adjustments
Range
Adjustment
Photo Eye
Red LED
Time Delay
Adjustment
Dip Switch
Switch 1 – Normal Mode/Fail-Safe Mode
Choose Normal Mode if you wish the N.O. contact to remain
open if the power were to fail. This is the factory setting.
Choose Fail-safe Mode if you wish the contacts to close upon
power fail. Move the Dip switch to OFF position, and wire your
device to the Common and N.C. wires.
Switch 2 – Time Delay Mode/Toggle Mode
Factory setting is Time Delay (Sense) mode, whereby the
contact closure will be adjustable from 1 – 5 seconds using the
Time Delay Potentiometer.
In Toggle (or Switch) mode, when the CM-324 is activated
once, the relay will stay energized until it is activated once
again (adjustable timer is inactive in this mode).
Switch 3 – LED On/LED Off
This switch disables the LED, should this feature be desired.
Factory setting is ON. Once the Dip switches have been set, and
the unit is installed in the frame or enclosure, apply power to
the unit and observe operation.
Set both potentiometers to minimum setting initially
(fully counter-clockwise). See Diagram 3 for location.
Adjust the range potentiometer by turning
the pot in a clockwise manner, and passing your hand in front of
the unit. Rotate the pot until the desired range is obtained.
See Diagram 5 for patterns.
Next, adjust the time delay potentiometer by turning clockwise
until the desired time delay is obtained. It is sometimes
beneficial to leave this adjustment set to minimum and utilize
the time delay on the door operator, if present.
Wiring
Pigtail
CM-324
Red
12-24V
Power
Red
Blue
N.O.
Green
COM
Violet
N.C.
CM-324 SERIES ACTIVE INFRARED "HANDS-FREE" SWITCH
NOTE:
Timer is non-functional in
Toggle Mode.
Install the faceplate using
the screws provided.
NOTE: Do not overtighten
OPTIONAL
Apply the included Wheelchair
logo to the frame or wall at
desired location. See Diagram 5.
NOTE: Do not apply directly
to the faceplate
If using this product with an
Automatic Door, proceed to
Section 5 for System
Inspection Instructions.
5. SYSTEM INSPECTION INSTRUCTIONS
After the Installation and operational check of the system:
1. Place warning label on the door (as per ANSI A156.10 or
A156.19 guidelines). This will advise the person entering
the swing side zone that the door will move.
2. Instruct the owner on door system operation and how to
test it. This should be checked on a daily basis.
3. Instruct the owner on what to do if the door or any of its
components become damaged.
4. Strongly recommend to the owner that the complete entry
be inspected twice a year as part of the service agreement.
6. WARRANTY
Camden Door Controls guarantees the Sure-Wave™ to be free
from manufacturing defects for 3 years from date of sale.
If during the first 3 years the CM-324 fails to perform correctly,
it may be returned to our factory where it will be repaired or
replaced (at our discretion) without charge. Except as stated
herein, Camden extends no warranties expressed or implied
regarding function, performance or service.
INSTA LL AT ION INS T RUCT IONS
Diagram 5 - Wheelchair
Sticker Placement
Door Frame
CM-324/N3
1"
(25mm)
Page 3 of 4