CM-331 & CM-332 Active Infrared "Hands-Free" Switches Installation Instructions
DIP Switches
Scenario
1
2
9
OFF
ON
OFF
10
OFF
ON
11
OFF
ON
OFF
12
OFF
ON
DIP Switches
Scenario
1
2
13
ON
ON
OFF
14
ON
ON
15
ON
ON
OFF
16
ON
ON
* In Security Mode buzzer beeps when unit is triggered and when door is closed
** In Toggle Mode buzzer beeps twice when RL1 is toggled on and beeps once when RL1 is toggled off
Motion
Sensing
3
4
Mode
OFF
ON
OFF
Maintained
ON
ON
ON
Motion
Sensing
3
4
Mode
OFF
Dynamic
ON
OFF
ON
ON
ON
OPR
Relay1 activates as per POT2. Relay1 operation time will
continually reset if obstruction remains in front of unit. When
Simple
object is removed, Relay1 will operate as per POT2. No alarm
generated.
Relay1 activates as per POT2, delay as per POT3, Relay2
activates after the delay as per POT4. Relay1 and Relay2
operation will continually reset if obstruction remains. When
Sequence
object is removed Relay1 and Relay2 will operate according to
their respective POTs and Relay2 will deactivate X seconds after
Relay1 according to the set delay. No alarm generated.
If door is closed Relay2 activates, delay begins as per POT3,
Relay1 activates after the delay as per POT2. Relay2 deactivates
only when door is closed. If the door is closed before Relay1
activates, Relay1 will still activate. If the door is already opened
when the unit is triggered (due to the unit already being
triggered), Relay2 will already be active and remain active until
Security*
door is closed, Relay1 will activate after the delay. If the door is
already opened but not because the unit was triggered, Relay2
will activate, the delay begins as per POT3, Relay1 will activate
after the delay as per POT2. If object is kept in front of the
unit, Relay1 operation time will continually reset. Once object
is removed, Relay1 will operate according to POT2. Alarm is
generated if door is sensed open for 30 seconds.
Relay1 toggles, Relay2 activates (as per POT4). Relay2 only
activates when Relay1 is toggled on. If object is kept in front of
Toggle**
unit, Relay1 will stay in the same state and Relay2 operation
time will continually reset (if Relay2 is active). No alarm
generated.
OPR
Relay1 activates as per POT2. If the object is kept in front of the
unit, Relay1 will operate once and the unit will dynamically adjust
its maximum envelope to compensate for the object placed in
Simple
front of it. Once the envelope has been adjusted the unit will be
able to re-trigger. If object is not kept in front of unit the unit will
operate the same as Scenario 1. Alarm is generated if the object
is within 6" of the unit.
Relay1 activates as per POT2, delay as per POT3, Relay2
activates after the delay as per POT4. If object is kept in front
of unit, Relay1 and Relay2 will operate once and the unit will
dynamically adjust its maximum envelope to compensate for the
Sequence
object placed in front of it. Once the envelope has been adjusted
the unit will be able to re-trigger. If object is not kept in front
of unit the unit will operate the same as Scenario 2. Alarm is
generated if the object is within 6" of the unit.
Security*
Disabled - Error led and Relay1 led flash alternatively.
Reserved for Optical Programming - Error led and Relay1 led
Toggle**
flash together.
Page 8 of 8
Operation
Notes/Observations