- ページ 16

コントロールパネル CAME 319U36ENのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。CAME 319U36EN 19 ページ。 Control panel for 24v gearmotors

Memorisation
CH1 = Channel for direct function command to gearmotor control panel ("open only" command / "open-close-invert" command o
"open-stop-close-stop", depending on selection made on DIP switches 2 and 3).
CH2 = Channel for direct commands to an accessory device connected on B1-B2.
1) Keep CH1 button pressed on the electronic card. The LED fl ashes ON and OFF.
Flashing LED
CH1
2) Press the button on the transmitter you want memorised. The LED will stay ON to confi rm memorisation is OK.
T1
LED on
3) Repeat the procedure from point 1 and 2 for the "CH2" button associating it to another transmitter button.
T2
CH2