Troubleshooting

If 3DGence DT3 does not run - no power to the
display.
l• Verify the power switch is turned on, the system
is plugged into a power source, and that power is
available.
• Verify adequate water level in the tank. If water
level in the tank drops below 2.54cm (approxima-
tely) from the top of the tank, 3DGence DT3 is
designed to power itself off.
• Check for tripped main circuit breaker. There is a
circuit breaker located behind the tank, facing
down. After having thoroughly drained and unplug-
ged the system from it's power source, tip the unit
so that it's resting on it's left side (when viewed
from the front panel). Locate the circuit breakers
(see Figure 5) looking up from the bottom of the
system, behind the tank. The circuit breaker has
tripped if the position of the breaker switch is
showing white. Reset the breaker by pushing it in.
A tripped circuit breaker usually indicates some
other problem ... with the system still on it's side,
spot check that all wires are undamaged.
If 3DGence DT3 heats with no water agitation.
• Check for tripped pump circuit breaker. There is a
circuit breaker located behind the tank, facing
down. After having thoroughly drained and unplug-
ged the system from it's power source, tip the unit
so that it's resting on it's left side (when viewed
from the front panel). Locate the circuit breaker
(see Figure 5) looking up from the bottom of the
system, behind the tank. The circuit breaker has
tripped if the position of the breaker switch is
showing white. Reset the breaker by pushing it in.
3DGence DT3
3DGence DT3
pump circuit
breaker
• If the pump motor feels hot (to the touch), the
temperature sensitive thermo switch may be
tripping due to high heat. Remove any obstructions
from the drain filter and jets (refer to the mainte-
nance section) and allow the pump to cool down
before restarting.
Parts take an abnormally long time to clean
• Check the temperature of the water. Optimal
temperature is 65C.
• Cleaning times are faster with fresh cleaning
solution. Change the solution whenever the water
gets too dark (coffee brown in color).
• Check that the suction strainer and the manifold
jets are clear of debris per the maintenance
instructions.
Jet action cleaning
Jet action cleaning
main circuit
breaker