16 PRODUCT AND THE ENVIRONMENT
The air purifier is made from lead-free components. It can be recycled. Used models must al-
ways be sent to a recycling station for correct recycling and/or disposal of parts and components.
17 FILTERS AND THE ENVIRONMENT
Note that filters must not be disposed of along with ordinary household waste. Scrapped filters
must always be correctly taken care of and handled safely. Recycling or disposal must always be
carried out at an approved waste facility. If you have any questions about this, please contact your
local authority or distributor for advice on correct care.
18 MAINTENANCE
If necessary, the unit can be cleaned using a mild cleaning agent.
BEFORE CLEANING, ALWAYS SWITCH OFF THE MACHINE AND PULL OUT THE ELECTRICAL
CONNECTOR!
REPLACING THE FUSE:
THIS OPERATION MUST BE CARRIED OUT WITH THE CITY L UNIT DE-ENERGISED.
1.
Pull out the fuse cover using a flat-head screwdriver.
The fuse cover is allocated on the bottom of the socket.
2.
Carefully remove the fuse.
3.
Replace the fuse with a fuse 2A 250V.
4.
Close the fuse cover.
19 INSTRUCTIONS FOR REPLACING FILTERS
WARNING! When handling used filters, personal protective equipment such as protective gloves
and masks must be used. To choose the correct type of respiratory protection, consult either the
safety representative / officer at your workplace or the manufacturer of the respiratory protec-
tion.
Used filters may contain harmful substances and particles. With incorrect handling, these can
escape to the environment and present risks of sickness and ill health.
Filters should be replaced on a continuous basis. See Camfil AB's recommendations concerning
the frequency of filter replacements.
14
Camfil – Clean Air Solutions
20 FILTER REPLACEMENT
ALWAYS USE PROTECTIVE GLOVES AND RESPIRATORY PROTECTION WHEN HANDLING USED
FILTERS! Risk of ill health and sickness.
1. Switch off the unit by turning the safety
switch or remove the electrical connector.
Make sure that the blue operating LED's
is off.
2. Lift off the top cover of the unit.
3. Push and unscrew the four buttons and
lift up the hatch.
4. Use the handle and pull the hatch
upwards.
5. Grip the filter and pull it towards you.
Put the filter in a plastic bag. Do the same
procedure on the other filter and put it in
a plastic bag.
6. Take a new HEPA filter out of its box.
NB! DO NOT TOUCH THE FILTER'S
SURFACE. HOLD THE FRAME ONLY!
Put the filter in its positioning, press it
down and against the pattern of holes.
The black gasket must be towards the
hole pattern of the unit.
Do steps 1- 6 in reverse order.
Camfil – Clean Air Solutions
15