6. Technical data

6.1 General

Measured quantity:
Measuring principle:
6.2 Measuring input
Measuring range:
Inclination angle:
Sense of rotation:
6.3 Measuring output
Power supply:
Output signal:
Current consumption:
6.4 Accuracy
Linearity:
Repeatability::
Resolution:
Temperature coefficient:
6.8 Dimensions
PM 1002077 000 00
Tilt angle
Microelectromechanical capacitive
tilt system
-180° ... +180° free programmable
Set to ±180°
Adjustable for rotation clockwise
or counter-clockwis
e
18 ... 33 VDC
4 ... 20 mA at max. 250 Ω
< 50 mA
0,2°
0,1°
6 µA (12 bits / 25 mA)
~ 0,2° / 10K
Inclination transmitter KINAX N705-MEMS 4...20 mA
6.5 Installation data
Material:
Mounting position:
Electrical connection:
Weight:
6.6 Regulations
Spurious radiation:
Immunity:
Test voltage:
Housing protection:
6.7 Environmental condition
Climatic rating:
Vibration resistance:
Shock resistance:
Transportation and
storage temperature:
Housing cap: (3.2382)
Aluminium
Perpendicular to the measurement
objec
Connector M12x1,5 / 5 poles
appr. 0,3 kg
EN 61 000-6-3
EN 61 000-6-2
500 Veff., 50 Hz, 1 Min.
IP 67 acc. to EN 60 529
Temperature -30 ... +70 °C
Relative humidity ≤ 95%
≤ 40 m/s
/ 5...100 Hz
2
acc. to EN 60068-2-6
500 m/s
/ 18 ms
2
acc to EN 60068-2-27
-30 ... +70 °C
11/12