Display LED and operating elements
For each input channel the module has a green status LED, which is lit if there is a direct power voltage of more
than 10VDC available. Input signals can be simulated with the two buttons. This may be helpful in cases of
support or tests or while in operation. For simulation purposes, each, the status LEDs and the buttons have two
different functions.
Indicator
Designation
LED Green
PWR
LED Status
Status
1 – 8
LED Green
(8x)
Button
Designation
Button 1
MAN/Select
Button 2
ON/OFF
10
Software / Control
The 1-Wire interface of the module can be read out by 1-Wire commands for the DS2408 component.
The module is a standard module for many systems and software programs, like ESERA STATION, PowerDog,
SmartOne, FHEM, OWFS, IP-Symcon and many more.
10.1
Data Output 1-Wire Controller / 1-Wire Gateway
The 1-Wire interface of the 8-Fold Digital Input is being read by standard commands for the DS2408 device. For
the 8-Fold Digital Input, the following data are output for binary / digital inputs. The input value will be output as
decimal value 0-254. In a second data set output will be with binary display (0 and 1). Each input has a value,
which is added up in each case.
Input Value:
Input 1 = 1, Input 2 = 2, Input 3 = 4, Input 4 = 8, Input 5 = 16, Input 6 = 32, Input 7 = 64,
Input 8 = 128.
Article number 11216 can be assigned to the DS2408 module by using the Config tool. After assigning the article
number the following formatted output will be received:
Data Output:
1_OWD1_1|8
1_OWD1_2|10000000
Further information for options and commands can be found in the latest available documentation for
1–Wire Controller / 1–Wire Gateway.
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de
Function
The LED has two different functions
LED is lit, indicator for 12V power supply
flashes when operated manually
The LED has two different functions
flashes while changes of the input status of all inputs
Manual operation: Input On/Off for elected channel
Input Status
LED is lit at the appropriate input if signal voltage is available
LED flashes if input was set by manual operation
Function
The button has two different functions
press and hold for 2 seconds to activate manual operation in order to
set the inputs
afterwards briefly press the button to select the input which should be
set
The button has two different functions
Input On/Off in manual operation when briefly pressed
press and hold for 2 seconds to deactivate manual operation for all
manually set inputs
=> controller no._module no._data set | input decimal value
=> controller no._module no._data set | input binary display
11216 V4.0 R1.0 Manual
Page 5 of 7