コントロールユニット esera automation 11211のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。esera automation 11211 7 ページ。 1-wire dual s0 counter module

3
Technical data
1-Wire device:
Operating voltage:
Current consumption:
Buffer time counter values:
Counter size:
Interface:
Connection:
S0 input:
S0 Voltage:
Counting frequency:
Length of supply cable S0:
LED indicators:
4
Ambient conditions
Temperature, operation: -10°C to +50°C
Humidity:
Dimensions:
Protection system:
Protection class:
5
Conformity
EN 50090-2-2
EN 61000-4-2, ESD
EN 61000-4-3, HF
EN 61000-4-4, Burst
EN 61000-4-5, Surge
EN 61000-6-1, Interference immunity
EN 61000-6-3, Interference radiation
RoHS
6
LED display
The module has two yellow LED displays, which flash when an input is being closed.
When the input is open, a 5V power is measurable. The edge is being counted during the closing of the input. A
continuously closed input does not cause a modification of the counter readings.
Display
Label
2 x LED
Input 1, Input 2
green
7
Software / Control
The component is being read out per 1-Wire commands for the DS2423 module. Details for a power counter can
be taken from a sample program in the download area of the shop.
8
Function S0 Interface
The S0 interface is suitable for all types of energy meters and wind turbines and should not be confused with an
S0 interface of ISDN telephone systems.
An S0 interface works according to the principle that e.g. an energy meter provides a defined number of pulses
for a certain amount of energy. Once the number of pulses related to the amount of energy, e.g. an electricity
meter, is known, the current electricity consumption can be calculated very easily.
9
How is an electricity consumption recorded / calculated?
Example: An electricity meter emits 1000 pulses per kW/h. One pulse corresponds to an output of 1W/h. If the
counted impulses are read in every 3 minutes and the delta to the last readout cycle was formed, we know how
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de
command set DS2423 (Dual Counter)
12 V= (+/-10%)
max. 15mA when both LEDs are on
unlimited
2 x 32 Bit Counter, resettable
1-Wire Bus (1-Wire Data (5V), 12V and GND)
screw terminals for 1-wire bus and S0 interface
2 x S0 interface (pulse inputs) for energy meters with isolated
S0 Interface according to DIN 43864
working voltage approx. 10VDC with approx. 3mA working current
max. 300Hz (300 pulses per second)
It is recommended to use a supply cable between S0 meter and sensor with
max 10m.
When using twisted pair and shielded cables max. 15m,
Depending on the EMC load of the environment, may also be less possible.
2 x LED green, lights when input is closed
10 - 92% (non-condensing)
17 x 71 x 90mm (WxDxH)
IP20
III
Function
Display of received pulses at the inputs
LED flashes in case of cyclically incoming pulses
LEDs flash continuously, if the respective input is closed.
11211 V2.0 R1.0 Manual