スイッチ esera automation 11233のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。esera automation 11233 7 ページ。 Binary output / dual switch module for 1-wire bus
7
Conformity
EN 50090-2-2,
EN 61000-4-2, ESD
EN 61000-4-3, HF
EN 61000-4-4, Burst
EN 61000-4-5, Surge
EN 61000-6-1, Fault-free operation
EN 61000-6-3, Stray radiations
RoHS
8
LED display and button
The module has two LED displays.
Indicator
Designation
LED Green
Output 1
LED Green
Output 2
Button
Designation
1 internal
Output 1 On/Off
2 internal
Output 2 On/Off
1 external
Output 1 On/Off
2 external
Output 2 On/Off
9
Button and 1-Wire Interfaces
In addition to the buttons on the top side of the module, the module has an external button-interface to connect
two external buttons (make contact). This means, light switches can be connected to the external button interface
to control on/off light commands. For connection regular light switches of all manufacturers can be used.
Within the module, a µ-controller takes over the query of the buttons, the 1-Wire interface and the control of the
relays. Flank control is used to query buttons and 1-Wire component.
The switching status of the relays can be set via the external and internal buttons. Relays can also be set by the
1-Wire Interface. The state of the relay can be read via the 1-wire interface.
External and internal control inputs:
Button interface, external button 1
Button interface, external button 2
Module top side, button 1 internal
Module top side, button 2 internal
1-Wire component, DS2413 channel 0
1-Wire component, DS2413 channel 1
Do not connect any kind of power source to the external button interface! Connecting cables among the module
and the button to other cables should be insulated. In idle mode 5 V direct power can be measured at the
connections of the button interface.
10
Software / Control
The component is being controlled by 1-Wire Commands for the component DS2413. The relay state will be read
out automatically by the 1-Wire Interface. Relays set via pushbutton interface or manual mode can be read back
via the 1-wire interface.
Available 1-Wire commands
Read ROM
Match ROM
Search ROM
Skip ROM
Read PIO Registers
Channel Access Write
All rights reserved. Reproduction as well as electronic duplication of this user manual, complete or in part, requires the written consent of
ESERA-Automation or E-Service GmbH. Errors and technical modification subject to change.
www.esera.de
LED Function
- LEDs flash at system start-up
- LED is lit when an output relay is active
- Indicator for power saving mode
- LEDs flash at system start-up
- LED is lit when an output relay is active
Button function
Button 1 has two different functions
Changeover of relay 2
Changeover of relay 1
Changeover of relay 2
33h
64-BIT ROM, RC-FLAG
55h
64-BIT ROM, RC-FLAG
F0h
64-BIT ROM, RC-FLAG
CCh
RC-FLAG
F0h
Input und Output Status, Bit 0-2 for Channel 0 und 1
5Ah
Port Output Latches / Status, Bit 0-2, values greater than 3 are ignored
11233 V1.0 R1.1 Manual
-
Changeover of relay 1
-
Power saving mode on/off
For details refer to chapter „Power saving mode"
ESERA-Automation, E-Service GmbH 2019
Page 4 of 7