TB0150.fm — Settings for 24-bit Color Not Available in Grid Center Client
OVERVIEW / ENVIRONMENT
24-bit color is not available in the current Grid Center I/Port clients on the Eon e100 and Capio One I/Ports.
ClearCube has issued an update for the Grid Center I/Port clients to enable 24-bit color within RDP ses-
sions.
DETAILED DESCRIPTION
24-bit color is not available in the current Grid Center I/Port clients on the Eon e100 and Capio One I/Ports.
ClearCube has issued a set of software updates that enable 32-bit color depth on the I/Port. These updates
should be applied to all Eon e100 and Capio One I/Ports using the Grid Center client for which 24-bit color
support on RDP is desired. The updates can be applied as local installations, or remotely as snap-ins. ezRe-
mote Manager software is required to install this snap-in remotely.
Note: Do not use these patches on I8010 or I8800 I/Ports.
This patch is available on the ClearCube Support Website as:
GridCenter_client_24_bit_change.zip
This file contains the following:
A folder titled ezRM_patch that contains the following:
A subfolder named Linux that contains the ezRemote Manager snap-in for Linux
A subfolder named XPe that contains the ezRemote Manager snap-in for XPe
A folder titled Standalone_patch that contains the following:
A subfolder named Linux that contains the patch and a
A subfolder named XPe that contains the patch and a
This Technical Bulletin.
To install the patch using ezRemote Manager:
For XPe, do the following:
1. Download and unzip the
2. Copy the ezRM_patch folder to the ezRemote Manager server.
3. Start ezRemote Manager and select the I/Port(s) to be patched.
4. Click the Snapin Manager icon in the menu bar.
5. Browse to the
\\ezRM_patch\XPe\
The snap-in is installed and the I/Port reboots when the installation is complete.
Note: Before pushing the patch to an XPe I/Port, please see Technical Bulletin TB0149, ezRemote Man-
ager Patch for XPe Write Filter.
ClearCube Technology
8834 Capital of Texas Hwy N
Settings for 24-bit Color Not Available in Grid Center Client
Eon e100 and Capio One I/Ports, Grid Center Client
August 30, 2005
GridCenter_client_24_bit_change.zip
folder, select the
Austin, Texas 78759
ClearCube Public Technical Document
Document Code: TB0150MH
file that installs it
.sh
file that installs it
.bat
file.
file, and click OK.
install.2do
voice 512 652 3500 www.clearcube.com
TB0150 rev 8/30/2005