- ページ 15

温度コントローラー dixell COOL MATE XLH360のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。dixell COOL MATE XLH360 16 ページ。 Cool mate temperature and humidity controller for seasoning-maturing cabinets

dixell COOL MATE XLH360 取扱説明書
dIXEL

16. XLH360 WIRING CONNECTIONS

HO T KEY
35 36
RS 48 5
1 2
3 4 5 6 7 8 9 101 1 12 13
Conf. Do or

17. DEFAULT SETTING VALUES

Dripping Phase
Running Phase
Stopping Phase
Label
Value
Menu
dbt
2.0
Pr1
dbH
5.0
Pr1
LS
-40.0
Pr2
uS
110
Pr2
odS
1
Pr2
Ac
1
Pr1
tHu
c-H
Pr2
LSH
0.0
Pr2
uSH
100
Pr2
cF
°C
Pr2
rES
dE
Pr2
rEH
Hd
Pr2
trC
co
Pr2
tdF
rE
Pr2
EdF
in
Pr2
SdF
0.0
Pr2
dtE
8.0
Pr2
idF
6
Pr1
MdF
20
Pr1
dFd
it
Pr2
dAd
30
Pr2
Fdt
0
Pr2
dPo
no
Pr2
Hud
no
Pr2
Fnc
c-n
Pr2
rFi
0
Pr2
rFd
0
Pr2
ALc
Ab
Pr2
ALL
-40.0
Pr1
ALu
110
Pr1
ALH
1.0
Pr2
ALd
15
Pr2
dAo
1.3
Pr2
EdA
20
Pr2
1592017410 XLH360 GB r1.0 15.04.2005.doc
Operating Instructions
20A 250V
16FLA(96 L RA )
20A 250V
16 FLA (96L R A)
14
151 6 17 18
19 20
21 222 3 24 25 26
In
NC
12V§ gnd
Comp
Hea ter
Input
4÷20mA
110 Vac Power Supply: connect to 33-34 terminals
Set temperature
5.0 °C
5.0 °C
-
Description
Half dead band width for temperature
Half dead band width for humidity
Minimum temperature set point limit
Maximum temperature set point limit
Outputs activation delay at start up
Anti-short cycle delay
Humidity regulation
Minimum humidity set point limit
Maximum humidity set point limit
Measurement unit
Resolution (for °C):
Resolution for RH%:
Instrument behaviour at the end of the cycle
Defrost type
Defrost mode
Set point for SMART DEFROST
Defrost termination temperature
Interval between defrosts
Duration of defrost
Display during defrost
Defrost display time out
Draining time
First defrost after start up
Humidity control during defrost
Fan operating mode
Interval between 2 cycles of change of air
Duration of cycle of change of air
Temperature alarm configuration
Low temperature alarm setting
High temperature alarm setting
Temperature alarm recovery differential
Temperature alarm delay
Delay of temperature alarm at start-up
Alarm delay at the end of defrost
XLH360
cod. 1592017410
16A
16A
8 A
8A
2 50V ~
250V~
250V~
250V~
2728
29 30 31
33 34
Line
N
L i g ht
NC
Def
Supply
De-
Fa n
Hum
Extr.
120/230V~
Hum
Set humidity
Duration
- -
5.00 h
50.0 RH%
5.00 h
-
5.00 h
Range
0.1°C o 1°F ÷ 25°C o 77°F
0.5 ÷ 50
-50.0°C o –58°F ÷ Set T
Set T ÷ 110°C o 230°F
0 ÷ 250 min
0 ÷ 30 min
db = dehumidifier relay.; cHu = dehum+
compr.; c-H= without dehum. relay
Lci ÷ Set H
Set H ÷ uci
°C ÷°F
in = integer / dE = decimal
in = integer / Hd = half digit
co=start holding, in=stop regulation,
cL=restart the first phase+End message; cLE
= restart the first phase
rE, rT, in
In, Sd
-30 ÷ +30°C / -22÷+86°F
-50,0÷110°C/ -58÷230°F
1 ÷ 120 h
0 ÷ 250 min
rt / it / SEt / dEF / dEG
0 ÷ 250 min
0÷60 min.
n ÷ y
no; yES
c-n / c-Y / o-n / o-Y
1 ÷ 120 h (0 = manual start)
1 ÷ 250 min (0 = manual stop)
rE = relative / Ab = absolute
0°C ÷ 50.0°C / -50.0°C ÷ ALu
0°C ÷ 50.0°C / ALL ÷ 110°C
0.1°C o 1°F ÷ 25°C o 77°F
0 ÷ 250 min
0.0 ÷ 23.5 h
0 ÷ 250 min
15/16