Dixon BAYCO PC5000 据付・取扱説明書
Inspection Procedures: It is our recommendation that in a mobile or trucking
application, the PneuClean filter element be inspected on a weekly
basis and changed at least every 12 months.
For PneuClean filter elements part numbers PC5001.
The following inspection procedure must be implemented in order for
the product warranty to be in effect. Any change or deviation from this
procedure voids the Dixon Bayco product warranty and removes Dixon
Bayco from any contamination liability.
Remove quick disconnect V-clamp, remove end cap.
CAUTION: Open slowly and listen for pressure.
Pull the element completely out of the assembly housing.
Carefully look into the housing at the bottom gasket and guide
plate.
Check to see if the white bottom gasket is in place and clean.
Replace if missing, broken or damaged. Clean the housing if dirty.
Check the inside of the sidewall of the housing for oil residue and
small particles. Remove with clean cloth, steam, or cleaning
device of choice.
Carefully inspect the outer surface of the filter element by looking
into the pleated area for very dark color media, oil or grease
residue, fiberglass fibers, and caked on product. If this surface
appears to have heavy deposits of contaminates such as metal,
iron oxide or caked on product, and/or the element has been in
service for twelve months it should be replaced.
Turn the element up on its end where you can look down into the
open end. Use a light or flashlight, if needed. Carefully look at the
sides of the element.
Inspect lid o-ring and replace if damaged.
Loosen adjusting bolt, replace lid and clamp ring. Tighten clamp
ring. Tighten adjusting bolt and lock nut. Replace acorn nut.
If the screen wire and/or media show signs of deterioration
replace immediately
If the screen wire and/or media do not show signs of
deterioration, but has been in operation for 12 months,
replace filter immediately.
If product is caked up inside this area, replace
immediately.
If the element has been run longer than 12 months replace
immediately.
40072PA R2