モニター Dixon Bayco FloTech FT208のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Dixon Bayco FloTech FT208 20 ページ。 Checkmate programmable retain / overfill onboard monitor
FloTech Programmable CheckMate Retain / Overfill Monitor
Cable Installation Instructions
FloTech recommends you use FT404 jacketed 11-conductor cable for up to 8 compartment systems. This cable
is specially designed to be oil, UV, and abrasion resistant. It incorporates a noble tin-plated stranded copper
wire which resists corrosion. When installed properly, this cable will provide years of reliable service. See the
Proper Wire Connections section for more detailed directions about stripping and terminating the cables.
Monitor Housing
After the monitor housing is mounted, install FloTech FT402 cable glands in the openings where needed.
These are, as illustrated in Fig.3: Power, Top Sensors, Bottom Sensors (if equipped) and Socket. Route the
lengths of FloTech FT404 cable through the conduit openings. Cut the cables to length leaving approximately 8
inches of extra length inside the monitor housing.
Unused conduit openings in the sensor housings must have a ½ inch NPT pipe plug installed. Note that when
using the FloTech FT390 Dual Socket Assembly, you only need to install one cable gland for the socket wiring.
Fig. 3
Monitor Housing Cable Routing Diagram
Wiring Instructions
Proper Wire Connections
Please read this section of the manual before attempting to wire the FloTech FT208 Monitor. This section
recommends some 'guidelines' for installing the system wiring that, when done properly, will insure a long,
trouble free service life for your equipment.
CABLE STRIPPING
FloTech recommends using FT404 eleven conductor cable to wire the Onboard Monitor System for up to 8
compartment systems. When stripping the rubber jacket from the cable, FloTech recommends using the
FT9023 or equivalent Cable Stripper. This stripper has an adjustable cutting blade depth setting. The depth
should be set to only cut through one-half to two-thirds of the outer jacket thickness. This will insure that the
insulation on the inner conductors is not nicked. Any nicks or cuts in the wire insulation can, over time,
degrade the quality of the wire and lead to intermittent or total failure.
CAUTION: Razor Knifes Will Cut The Inside Wire Insulation
SPLICE END CONNECTIONS
FloTech recommends using the FT9024 or equivalent Crimp Tool for securing the splice end connections.
Follow this process to secure each connection: