- ページ 2

ポータブル発電機 ClearWater Microzone 300PのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。ClearWater Microzone 300P 2 ページ。 Corona discharge ozone generator

ClearWater Microzone 300P オーナーズマニュアル
ACCESSORIES
Diffuser
Air Dryer
8' Clear Hose
OZONE GENERATOR
Front view
On/Off
Timer Control
Air Dryer
5' Power Cord
Bottom view
Ozone Hose Connector
Fuse Holder
INSTALLATION and
PLACEMENT INSTRUCTIONS
After unpacking the Microzone 300P please do the following:
CLEAR HOSE -
• Moisten one end and slide hose onto ozone hose connector located on bottom
of unit.
CHECK VALVE -
• Cut tube 6" from ozone hose connector. Slide one end of the blue check valve into
the open end of the hose connected to the ozone generator, making sure the flat
side of the check valve diaphragm housing is facing the ozone hose connector.
Slide an end of the remaining length of hose onto the other end of the check valve.
Check Valve
Two Screws
Back view
Wall
Mounting
Holes
Air
Inlet
Right side view
Air Dryer
Inputs
DIFFUSER
Connect diffuser to the open end of hose (before using the diffuser for the first time, blow
air through it to ensure proper airflow).
AIR DRYER
Attach air dryer to the right side of the unit labeled "Air Dryer Inputs".
UNIT PLACEMENT
• Any free counter space or wall space that is between 12" to 36" away from the
body of water and is close to a GFI- protected electrical outlet. Note: Do not allow
the ozone generator to come in contact with water at any time.
• Ozone generator may be wall mounted (using holes on back of unit) or simply placed on
a flat surface.
HOW TO USE MICROZONE 300P
1.
Submerge the diffuser in the body of water to a maximum depth of 10".
2.
Plug ozone generator into a GFI-protected outlet and turn unit on (when unit is
on, bubbles will begin rising from the diffuser).
3.
Allow several minutes to ensure diffusion of the ozone into the water.
4.
When finished, turn the on/off timer control to 'OFF' position and remove diffuser from
water.
MAINTENANCE
• Over time, diffuser may become clogged and result in air compressor damage. It is
recommended that the diffuser is cleaned once a month by submersing it in a solution
of 50% water and 50% muriatic acid for a few hours. Rinse thoroughly with water before
re-installing.
• Should the beads in the air dryer turn pink, excess moisture has entered the air stream
feeding the ozone generator. To remove the moisture, remove air dryer from ozone
generator and place it in a microwave oven for 15 to 30 seconds. Blow air through it to
insure proper air flow before re-installing.
SPECIFICATIONS
• Electrical - 120 volt, 60 Hz
• Dimensions - 3" x 5" x 9 1/2"
• Weight - 2 1/4 pounds
• Fuse - 2.0 AMP