- ページ 5

照明器具 ClearWater OzoneMax OZ-SPAのPDF インストレーション&オペレーションマニュアルをオンラインで閲覧またはダウンロードできます。ClearWater OzoneMax OZ-SPA 8 ページ。 Vacuum-ultraviolet pool ozone systems

MAKE SURE THE WATER FLOWS IN THE DIRECTION OF THE ARROW ON THE VENTURI INJECTOR
AND TO INSTALL IT IN THE CORRECT DIRECTION OF THE WATER FLOW.
The installation of the Kynar check valve is a precautionary one we require during installation in case of the
unlikely failure of the venturi that is built in the manifold. This would prevent water from entering the
OzoneMAX unit. To make sure this is properly installed, cut a few inches of the reinforced hose and insert one
end on the outlet coming out of the OzoneMAX unit. Install the check valve, then connect the other end of the
remaining piece of hose to the check valve and then to the venturi injector – which is located on the manifold.
It is important that you install the Kynar check valve where air flow is allowed toward the injector. Air direction
can be tested by blowing into the ¼" I.D. polybraid tubing. If correctly installed, you will see air bubbles enter
the ¾" I.D. clear vinyl tubing.
DO NOT SUCK ON THE ¼" I.D. TUBING WHEN CONNECTED TO THE OZONE SYSTEM.
After installation and turning on all the equipment, you will see a frothing (very tiny milk-like bubbles) action
immediately after the venturi injector. This is located on the ¼" clear vinyl hose. These tiny bubbles should
also appear at the nearest return line and possibly other return lines. This means ozone is getting injected into
the pool's water.
G. Installing the Venturi Injector
OZ-VIK - Venturi Injection Kit
L
O
I
J
M
N
G. (1) Mazzei venturi injector
H. (2) 2" slip x ¾" fpt x 2" slip tee
I. (4) ¼" nylon hose clamps
J. (4) 1 ¼" metal hose clamps
K. (1) ¼"x ¼" Kynar check valve
L. (1) 8' of ¾" ID vinyl tubing
M. (2) ¾" mpt to ¾" barbed adapter
N. (9) ¼"x 14" long zip ties
O. (1) 8' of ¼" reinforced vinyl hose
G
K
5
(continued)
H
H