1.1 DESCRIPTION
The LMD622 two channel and LMD624 four channel Nema TS-2 rack mounted inductive
Loop Monitor with DEFLECTOMETER
double-sided 44 pin edge connectors for connection of power, loop inputs and call outputs.
The units meet or exceed all requirements for a Type A, B, C and Type D detectors as
defined in Nema Standard TS2-2003 V02.06. Each channel has individual controls for
setting up sensitivity, operational mode and frequency on the front panel. Two high intensity
front panel LEDs indicate vehicle detection, timing operation and fault monitoring status for
each channel. Call outputs are available in either relay or optically-isolated solid-state
transistor form.
Model
Channels
LMD622
Two Channel
LMD622-R
Two Channel
LMD622T
Two Channel
LMD622T-R
Two Channel
LMD624
Four Channel
LMD624H
Four Channel
LMD624T
Four Channel
1.2 OVERVIEW
A dynamic Overview of the LMD622t operation which includes an interactive LMD
Simulator is available on the EDI web site, www.EDItraffic.com.
1.3 DEFLECTOMETER FEATURE
The LMD Series Loop Monitor introduces a concept to the inductive loop detector field that
revolutionizes the process of installing and programming a loop detector. The new user
interface of the LMD Series provides the feedback necessary to the signal technician to
quickly and accurately program the parameters of the detector exactly to the loop plus lead-
in system characteristics.
The DEFLECTOMETER
while a vehicle is in the detection zone. This provides feedback that the
unit is optimally tuned to detect vehicles of all sizes.
Setting the sensitivity level of the detector can be easily done in one step
with
a
DEFLECTOMETER
is changed. See section 2.1.1.
The simple push-button interface is intuitive and eliminates many of the
reliability problems found with tiny DIP switches of conventional detectors.
Operational mode, Frequency, and Sensitivity are all programmed and
displayed using the push-button interface. Settings are stored in non-
volatile memory.
Eberle Design Inc.
LMD622 and LMD624 Series
Operations Manual
Section 1
GENERAL
®
Series is built on the international card format with
Nema Type
TS-2 Type A
TS-2 Type A
TS-2 Type C
TS-2 Type C
TS-2 Type B
TS-2 Type B
TS-2 Type D
Why guess when you can know!
®
display shows the relative strength of the call
"typical"
vehicle
parked
®
display updates dynamically as the sensitivity level
Features
Relay Outputs
Delay & Extension Timing
Delay & Extension Timing, Relay Output
Half Width Front Panel
Delay & Extension Timing
in
the
detection
zone.
The