TM
The Model 242L/244L handle assembly is made of GE Lexan
Type 121, which is a super
durable polycarbonate resin. The design of this assembly strengthens and protects the whole
PCB assembly much better than conventional metal face plates.

1.4 INSTALLATION AND ADJUSTMENTS

Installation of the unit consists of plugging into the appropriate slot of the Input File and
connecting the assigned inputs to the proper cabinet terminals. The edge connector is keyed
to prevent incorrect installation. Following power-up, a front panel LED test will illuminate
both OUT indicators for two seconds.

1.4.1 MINIMUM OUTPUT PULSE

If desired, the output pulse width for both channels can be set to 100 milliseconds minimum
by installing jumper "100ms" (J4-A).

1.4.2 INPUT POLARITY

The polarity of the input can be inverted such that a closed contact input is False and an
open contact input is True. The input polarity of Channel 1 can be set to invert by installing a
jumper into the "CH1 POL" (J4-B). The input polarity of Channel 2 can be set to invert by
installing a jumper into the "CH2 POL" (J4-C). The input polarity of Channel 3 can be set to
invert by installing a jumper into the "CH3 POL" (J4-C). The input polarity of Channel 4 can
be set to invert by installing a jumper into the "CH4 POL" (J4-D).

1.5 THEORY OF OPERATION

Reference designators shown are for Channel 1. Reference designators for Channel 2 are
shown in parenthesis.

1.5.1 SYSTEM DESCRIPTION

The sensor circuitry can be broken down into seven major blocks. Each "Input Circuit" block
contains the electrical transient devices and the input biasing circuit. Although the Model
242L (244L) has two (four) DC inputs, a single digital processing section is used to process
both inputs.
The microcontroller unit "MCU" Block provides the input voltage threshold and input pulse
width filtering function on both channel 1 and channel 2 DC input circuits.
The MCU then controls the OUTPUT and DISPLAY blocks appropriately. The TEST switches
can be used to force the input to the True state. If the TEST switch is in the ON (locked) or
MOM (momentary) position it will force the output to the asserted (True) state regardless of
the input circuit state. The TEST switches are processed through the MCU for pulse width
input and output requirements.
Valid output calls are made via optically isolated solid state transistors. Output calls are
indicated on the front panel by means of red LEDs labeled "OUT".
Eberle Design Inc.