- ページ 6
産業用電気機器 EDI 244LのPDF 操作マニュアルをオンラインで閲覧またはダウンロードできます。EDI 244L 8 ページ。 Dc isolator unit
The Model 242L/244L operating voltage is generated by a high efficiency isolated switching
power supply. The resulting bias voltage supplied to the Input circuits is electrically isolated
from both 24VDC Logic Ground and AC Line Neutral. The VDD supply for the microcontroller
and display elements results from a post regulated 5 Vdc.
1.5.2 INPUT CIRCUIT
Resistors R21, R7, R8, R25, and R19 (R22, R9, R3, R26, and R20) provide the input bias
and voltage scaling circuit. The resulting voltage at U20.3 (U20.4) is then processed by the
microcontroller U20. Gas tube CR2 (CR3) and diode CR 14 (CR16) provides input electrical
transient protection.
1.5.3 MCU CIRCUIT
The microcontroller U20 processes the input voltages to perform the voltage threshold and
pulse width filtering functions. All signal processing is performed in the digital domain and
controlled by firmware embedded in the microcontroller. This unit does not rely on analog
delay, pulse, or comparator circuits for processing the input signals.
1.5.4 OUTPUT CIRCUIT
The output driver Q7 (Q8) is isolated from both the AC Mains and the internal GND reference
of the Model 242L by opto-couplers U8 (U9). CR9 (CR6) provides electrical transient
protection for the output driver Q7 (Q8).
1.5.5 DISPLAY AND SWITCH CIRCUIT
The LED indicator DS1 (DS3) for the channel output is driven directly from the microcontroller
U20. The input TEST switch SW1 (SW3) can be used to force the input state to the active
status.
1.5.6 POWER SUPPLY CIRCUIT
The main power supply is a fully isolated switching design. The cabinet 24VDC input voltage
is used to drive switching controller U18. The transformer T1 is used by controller U18 to
generate the isolated and regulated 19 VDC input bias voltage VCC that drives the input
circuits. The opto-coupler U21 and reference U25 provide the closed loop feedback to the
power supply controller U18 for regulation.
A second regulator U26 generates the 5.0 Vdc internal supply voltage VDD used by the
processor circuit from the 19 VDC bias. Inductor L2, C29, C31, and C24 filter the regulator
U26 output to provide clean VDD to the processor.
1.6 MAINTENANCE
The Model 242L/244L requires no adjustments or preventive maintenance.
1.6.1 TROUBLE ANALYSIS
The following list should be used to trouble-shoot the Model 242L/244L installation. If the
Model 242L/244L unit itself is suspect, see Section 1.6.2 for a complete internal testing
sequence.
a.
Neither channel responds to DC inputs
a.
Power supply fault
The Model 242L/244L requires a nominal 24 Vdc input voltage. The unit will
operate at voltages as low as 10.8 Vdc, however, an input voltage below this may
result in the unit entering a reset state. In this case, the unit will appear to be non-
functional.
b.
Channel does not detect all inputs
Eberle Design Inc.
Page 3