OPERATION

NOTE:
The generator has been shipped without engine oil. Fill with oil or it will not
start.
Do not tilt the generator when adding engine oil. This could result in
overfilling and damage to the engine.
1)
STARTING THE ENGINE
NOTE:
 Before starting the engine, do not connect electric appliance. FIG.14
A Electric start
1. Turn the fuel cock lever to the ON position. FIG.15
2. Turn the engine switch to the START position. FIG.16
3. Turn the engine switch to the RUN position. FIG.17
4. Warm up the engine without a load for a few minutes.
B Auto start
1.
Make sure the fuel cock valve to the ON position.
2.
Make sure the engine switch to the RUN position.
3.
Connect the cable to Auto Gen Start plug, as soon as the generator
receives the start signal, the generator will start. If the generator does not
start successfully, it will try to start again. Generator will disconnect the
circuit when the generator does not start after three times. FIG.18
2)
USING ELECTRIC POWER
1. AC APPLICATION
(a) Check the AC indicator light for proper voltage.
(b) Turn off the switch(es) of the electrical appliance(s) before connecting to
the generator.
(c) Insert the plug(s) of the electrical appliance(s) into the outlet. FIG.19
CAUTION:
 Be sure the electric device is turned off before plugging in.
 Be sure the total load is within generator's rating.
8
FIG.14
FIG.15
V
A
KW
HZ
MODE
FIG.16
V
A
KW
HZ
MODE
FIG.17
ENGINE
SWITCH
V
A
KW
HZ
MODE
STOP
RUN
START
FIG.18
V
A
KW
HZ
MODE
FIG.19