- ページ 5
セキュリティセンサー EDI LMD SeriesのPDF 操作マニュアルをオンラインで閲覧またはダウンロードできます。EDI LMD Series 15 ページ。 Deflectometer, inductive loop monitor
EDI LMD Series にも: 操作マニュアル (15 ページ)
LMD622 and LMD624 Series
Operations Manual
Loop diagnostic capabilities incorporated within the LMD Series Loop Monitor enable the
detection of short or open circuit loops and sudden changes of inductance exceeding 25
percent of the nominal inductance. Each type of fault is signified by the fault indicator
emitting a different flash sequence. This information can greatly assist the user in the
diagnosis of loop related problems.
The unit will detect inductance changes as small as 0.010% ∆L/L. Each channel is
sequentially energized and sampled so as to negate the possibility of crosstalk between
loops connected to different channels of the same detector.
Eberle Design Inc.
Page 2