5. The cooling fans inside the inverter do not work until the case temperature
reaches approximately 104°F.
6. If you do not plan to use the inverter for a long period of time, disconnect it from
your battery bank. Leaving the inverter on and connected for long periods of time
may harm the equipment and over discharge the battery.
SOFT START TECHNOLOGY
The soft start technology built into this inverter protects the unit from delivering too
much AC power at once by gradually increasing the AC voltage pushed out. To
make sure that you are utilizing this feature, turn on the appliance being used
before turning on the inverter. This is especially necessary for equipment that has
an inductive load or electrical
OUTPUT VOLTAGE & WAVEFORM
The electrical waveform output of this inverter is a pure sine wave, which has the
same quality as utility and/or domestic
most electrical devices, appliances and tools. This pure sine wave unit provides
more capabilities than modified sine wave inverters because it is a cleaner form of
power. The pure sine wave also effectively reduces the noise produced while using
appliances.
PROTECTIONS IN THE INVERTER
1. Input under-voltage alarm: When the input DC voltage is lower than 9.8V, the
buzzer will whistle intermittently to remind that the inverter will go into the
under voltage protection.
2. Under voltage protection: The inverter will automatically shut down when the
input DC voltage is lower than 9.5V. The buzzer will whistle continuously and
the green light is off, red light is on. Please turn off the inverter and use it after
recharging the battery.
3. Over voltage protection: The inverter will automatically shut down when the
input DC voltage is higher than 16V. The buzzer will whistle continuously and
the green light is off, red light is on. Please turn off the inverter and adjust the
input voltage to the admissible range.
4. Overload protection: The inverter will automatically shut down when the load is
higher than the rated power. The buzzer will whistle continuously. Turn off the
inverter and resume to normal operation after taking away the excessive load.
5. Short-circuit protection: The AC output will be automatically shut down when
short circuited. It will automatically reset after the problem is solved.
6. Thermal protection: The unit will get hot during operation. If the temperature is
higher than 149°F, the inverter will automatically shut down. Then the buzzer
motor.
power.
This type of waveform is suitable for