- ページ 16
産業機器 Altronic 6715 DのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Altronic 6715 D 20 ページ。 Coaxial load resistor
PERSONNEL WORKING ON THIS LOAD MUST BE
CONSIDERED SKILLED AS DEFINED BY
BEFORE PERFORMING ANY MAINTENANCE:
1.
DISCONNECT POWER AND ALLOW MOTOR TO COME TO A
FULL STOP.
2.
DISCONNECT RF CONNECTOR ASSEMBLY AND LOCK OUT
TRANSMITTER OPERATING CONTROLS.
3.
DISCONNECT TRANSMITTER INTERLOCK LINE.
FAILURE TO FOLLOW THESE DIRECTIONS
MAY CAUSE FATAL ELECTRICAL SHOCK!
5-1. Cleaning. The enclosure of the Model 6715D is finished with an acrylic finish or other
durable coating system. It should be cleaned with a neutral plastic and glass cleaner such
as Windex or Glass Plus. The RF connector should be cleaned with a non-residue contact
cleaner. Remove dirt accumulations from the fan and motor by vacuuming. Do not use
solvents or an air jet, as these can damage the motor. Remove dirt and dust accumulations
from the grills and resistor assembly with an air jet and a soft brush.
Lubrication.
5-2.
The fan pillow blocks, if used, are lubricated at the factory with quality lithium-
based high temperature grease. Each pillow-block assembly has a bearing which must be lubricated
periodically
with ordinary lithium-based grease designed for ball-bearing lubrication. The motors
are factory lubricated and are not designed to be lubricated in the field except under severe
conditions.
5-3. RF Circuit. The RF circuit does not require any periodic maintenance and the only repairs
possible are the replacement of parts in the connector, quick-step or support portions of the
resistor assembly or the replacement of resistors.
The resistors are hard, brittle ceramic material. It is very important to
avoid impact and excessive force when installing or removing them.
6715D/Rev. Jul.2020
SECTION V
MAINTENANCE
WARNING
EN60215 SECTION 3.1 AND APPENDIX D
CAUTION!
Page 16
Altronic Research Inc.