Setup
2.2 SETTING THE CURRENT TIME
P
ress the "Menu" button on the front of the timer. The unit is now in "Menu Mode" and the screen should display the
"CLOCK ADJUST" and "DATE ADJUST" options.
Use the UP and DOWN buttons to navigate through the options.
Press the ENTER button when the CLOCK ADJUST option is highlighted.
The Clock Adjust screen should now appear. Follow the on screen prompts to update the time.
Pressing the Menu button at any time will exit the menu structure and return the user to the Main Screen.
2.3 SETTING THE CURRENT DATE
P
ress the "Menu" button on the front of the timer. The unit is now in "Menu Mode" and the screen should display the
"CLOCK ADJUST" and "DATE ADJUST" options.
Use the UP and DOWN buttons to navigate through the options.
Press the ENTER button when the DATE ADJUST option is highlighted.
The Date Adjust screen should now appear. Follow the on screen prompts to update the date.
Pressing the Menu button at any time will exit the menu structure and return the user to the Main Screen.
2.4 AUDIO CONNECTIONS
Audio Output:
This output consists of stereo RCA sockets with an output of 0dBm into a 600Ω input. This is suitable for most PA
amplifier auxiliary inputs.
Rear Panel Volume Controls:
The output levels of the Prebell, Bell and Music tones can all be adjusted via trimpots located on the rear of the unit.
2.5 DIP SWITCH SETTINGS
The A 4510 has optional settings which are set by the DIP switches on the rear of the unit.
New settings will be effective when power is switched back on.
Switch 1
This switch is used to loop the Bell tone, or play the Bell tone only once after it has been triggered. (Note: this affects only
the automatic activation of the Bell tone. It does not apply to manual operation of the front Bell button).
OFF = Loop, ON = Play Once
Switch 2-8 Not Used.
www.altronics.com.au
IMPORTANT NOTE:
Ensure power is switched off when adjusting DIP switches.