CC 15 CRIMPER CALIBRATION
Calibration Check:
While the CC15 Crimper is calibrated at the factory prior to shipment, a calibration check is recommended
prior to using the crimper. Select a typical hose and fi tting and set the CC15 micrometer to the hose and
fi tting manufacturer's recommendation. Insert the hose and fi tting and press and hold the Start/Stop switch
until the crimper shuts off. Measure the fi nished crimp. If the fi nished crimp diameter is not within the hose
manufacturers specifi cations, recalibrate the crimper.
Note: Due to variations in hose and fi tting tolerances, some "offset" may required to achieve the
correct crimp diameter for specifi c hose and fi tting combinations across the range of hose and fi ttings
being crimped. If crimp diameters are consistently too large or consistently too small, the crimper
should be recalibrated.
Calibration:
While the crimper can be calibrated using any recommended
hose and fi tting combination, using a hose and fi tting combination
close to the size most frequently crimped will minimize the offset
required for other sizes and combinations of hose and fi ttings.
•
Select a hose and fi tting combination recommended by the
hose manufacturer and continue to adjust the Crimp Adjustment
Micrometer until the correct measured crimp diameter is achieved.
For example, if there is a 10mm die set in the crimper and the
required crimp diameter is 12.5mm the micrometer would be set to
crimp at 10mm + 2.5mm or 12.5mm.
Note: The number on the Crimp Adjustment Micrometer
may not agree with the hose manufacturers specifi cation
at this point.
•
If necessary, loosen the set screw on the knob with a .050 hex
key wrench and rotate the knob until the setting on the knob
matches the actual diameter of the fi nished crimp.
•
Tighten the set screw
•
Calibration is now complete
Page
6
Knob Set Screw