- ページ 8

DJ機材 djpower TOPCAT HF-90のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。djpower TOPCAT HF-90 13 ページ。 Flame machine

Menu Page
Error and Warning
Page
5.3.3.
Menu Map Setup
Press MENU to enter the setting interface. Press MENU to enter different options until you return to the main interface.
5.4.
Operation
5.4.1.
Orientation
Please read the safety distance print on the top panel of the FLAMER carefully.
DMX address:
1
DMX MODE:
2CH
Tip switch
ON
Language
Chinese
E1: Pressure Err
P:0 V:12
E2: Tip Err
P:0 V:12
E3:
Bat Err
P:0 V:12
E4:
System Lock
P:0 V:12
E5: Relief Err
P:0 V:12
Setting DMX address
Switch between 2-channel or 6-channel mode
Setting the tilt protection
(In case it is ON, if the machine tilts over 45° , it
stops the unit from firing)
Language setting
Pressure failed to reach 100% after 13s pressurizing,
system will report E1.
Possible fault: No fuel; pump failure; pipeline
problem etc.
The machine tilts over 45° , it stops running, system
will report E2
Machine stops running due to battery voltage
higher than15V or lower than 10V for 5s
contentiously.
Possible fault: the battery is low.
Safety lock located at TEST MODE
Pressure relief error due to pipeline can't release
pressure.
Possible fault: pressure release valve failure; pipeline
problem or control system problem etc.
- 6 -
1~512
2CH/6CH
ON/OFF