照明器具 Artistic License Data-Lynx O/PのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Artistic License Data-Lynx O/P 13 ページ。
Product Overview
Data-Lynx O/P is a rack-mounted Ethernet-to-
DMX512 converter. It is capable of converting
12 Art-Net Universes to DMX512 & RDM, or
12 sACN Universes to DMX512.
All ports can be set to a common Sub-Net
using the wheel selector on the front panel.
Individual port configuration is achieved over
the network using the internal web-server
or DMX-Workshop (free-of-charge software
available from Artistic Licence). When used
with Art-Net 3, DHCP is supported for
automatic IP address allocation.
Data-Lynx O/P can be mounted in a 19" 1U
Rack Enclosure using the supplied Rack Ears.
It is supplied with a standard IEC connector.
Summary of Key Features
Internal Ethernet switch and two RJ45
y
ports (Ethercon) enable multiple units to
be connected in series.
12 DMX512 ports, compatible with all
y
variants of DMX, including DMX512-A.
Support for RDM (Remote Device
Management) V1.0 (E1.20 - 2006 ESTA
Standard)
Universal mains input
y
Ethernet status indicators
y
DMX port status Indicators
y
Sub-Net wheel
y
Default IP address 2.x.y.z
y
Internal web-server for configuration of
y
DMX and IP settings (including support
for DHCP when used with Art-Net 3).
Detachable rack ears
y
Data-Lynx O/P User Guide
Power Supply & Earthing
The internal power supply requires an input
in the range 90-250 VAC with an Earth
connection. The mains fuse should only be
replaced with a 3.15A slow blow fuse.
The table below summarises the internal
Earth interconnection and isolation.
(Please note that we use the term Earth-
Ground to avoid international confusions. In
Europe Earth-Ground is called Earth; in the
USA Earth-Ground is called Ground).
Circuit
Chassis
Bonded to Earth-Ground
Type
Pin 1
DMX512
Ports
Shell
Type
Ethernet
Screen
Internal
Connects to Earth-Ground via 10
Logic
Ground
Ethernet Connection
Data-Lynx O/P has two RJ45 (Ethercon)
connections (one front, one back). The
product accepts Art-Net (the public domain
protocol invented by Artistic Licence) and
sACN (the standard managed under ESTA/
PLASA E1.31). Data-Lynx O/P requires Cat
5 cable or better and supports 10BaseT and
100BaseT.
Ethernet Indicators
The front panel ethernet connection has LED
data indicators (pictured on the next page),
which have the following meanings:
PWR: Power LED
LINK: ON if there is a valid link between this
connection and another valid Ethernet device.
ACT: Flashes when there is data activity.
SPD: ON if this connection is running at
100BaseT, OFF if running at 10BaseT.
Description
Ground referenced
Connects to Internal Logic
Ground
The connector shell is
connected to chassis
Transformer isolated
Connects to Earth-Ground
via 75 Ohm resistance &
100 pF capacitance, as
specified in IEEE standard
Ohm resistance
Page 4