- ページ 2
ゲートオープナー DKS 9200 "Full Open"のPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。DKS 9200 "Full Open" 2 ページ。 Mounted on the pedestal mounting stand
QUICKSTART "BASIC" GUIDELINES FOR MODEL 9200 - DIP-SWITCH AND WIRING REFERENCE
Model 9200 is intended for installation only on sliding gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the Installation/Owner's manual.
SW 1 DIP-Switches (Right Hand Side)
Switch
Function
Setting
Changes the direction
1
the operator will
open/close the gate.
Auto-Close
2
Timer
Exit Loop Port
Jumper Wire
Needed
3
Output
See Manual
Full Open Input
SW 1
4-OFF
Relay Activation
Upside-Down on Circuit Board.
and
4-OFF
4 and 5
LED Indicator
4-ON
Light Activation
4-ON
Warn Before
6
Operate
7
Reverses Gate
Stops Gate
Quick-Close
8
Timer Override
SW 2 DIP-Switches (Left Hand Side)
Switch
Function
Setting
1
Self-Test
Gate Opens
SW 2
2
Uphill
Upside-Down on Circuit Board.
Gate Opens
3
Downhill
4
Spare
SW 1 - Right 8 Switches
Description
Opening direction
Opening direction
using ON setting.
using OFF setting.
Lower Configuration
Auto-close timer is OFF. Manual input required to close gate.
OFF
Auto-close timer is ON. Adjustable from 1-23 seconds to close gate.
ON
OFF
The output wired to terminal #4 becomes the output from the loop detector
installed in the EXIT loop port. Plug-in loop detector required for "OFF" function.
ON
Normal Setting. Terminal #4 is a normal full open input for a single gate operator.
Relay activates and LED is ON when the gate is fully open.
5-OFF
Relay activates and LED is ON when the gate is not closed.
5-ON
Relay activates and LED is ON when the gate is opening and open.
5-OFF
Relay activates and LED is ON when the gate is opening and closing.
5-ON
Normal Setting. No sound.
OFF
Internal alarm will sound before gate starts and throughout gate's cycle.
ON
OFF
Normal Setting. Input to terminal #6 and/or reverse loops will REVERSE gate
during CLOSE cycle.
ON
Input to terminal #6 and/or reverse loops will STOP gate during CLOSE cycle.
OFF
Normal Setting. Timer will function normally.
ON
Opening gate will stop and begin to close as soon as all reversing inputs (Reverse
loops, photo sensors) are cleared regardless of the distance the gate has opened.
Note: After a DIP-switch setting is changed, power must be turned
OFF and then turned back on for the new setting to take affect.
SW 2 - Left 4 Switches
Description
OFF
Normal Setting. Normal gate operation.
ON
Self-test mode. Operator MUST be disconnected from gate to run self-test.
OFF
Normal Setting. Normal gate operation.
ON
MUST be ON if gate opens UPHILL.
Normal Setting. Normal gate operation.
OFF
ON
MUST be ON if gate opens DOWNHILL.
OFF
Leave in the OFF position.
Main Terminal
20 19 18 17 16 15 14
13
12 11 10 9
Red Full Open
Note: All stand-alone and
Green Close
telephone entry devices must
use a separate power source.
White Com
3-Button Control Station
DoorKing ONLY
SW 1 is Upside-Down on Board
SW 1, Switch 3 MUST be ON
except for dual operators or
Important:
Controls must be
exit loop partial open
far enough from the gate so
applications.
that the user is prevented
from coming in contact with
the gate while operating the
controls. Outdoor or easily
accessible controls should
have a security feature to
prevent unauthorized use.
Telephone Entry
"Optional" REVERSE GATE
for Closing Direction
Photo Sensors
Functions ONLY during gate closing cycle.
Key Switch
SW 1 is Upside-Down on Board
SW 1, switch 7: After photo sensor beam
gets obstructed:
OFF Setting - REVERSES GATE.
ON Setting - Stops gate then continues
closing when gate is clear (Same function
Stand-Alone
as UL 325 terminal #2).
Keypad
Note: The ON setting is used to help
prevent tailgating but the photo sensor
should be wired to the UL 325 terminal #2
when the "stop gate" function is desired,
see manual for more information.
Com
Stand-Alone
Card Reader
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
Auxiliary Common
Terminal
Connect any common
wire to these 2 terminals.
8
7 6 5 4 3 2 1
#1-Com
#2-Fully opens gate.
Safety Opening Device
#1-Com
#2 or #5-Relay
#3-24 volt
250 mamp. max.
3-Wire Radio Receiver
#1-24 Volt Power Com
#1-Relay Com
#2 or #5-Relay
#3-24 Volt Power
4-Wire Radio Receiver
#5 Terminal Note: Any opening
device connected to terminal #5 will
open the gate to the partial open
setting. Secondary entrapment
protection devices will also open the
gate to the partial open setting. If the
Inherent Reverse Sensor gets
activated during the close cycle, it
To #4 or #5