コンピュータ・ハードウェア Alula RE934ZTのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Alula RE934ZT 4 ページ。 Translator and zwave expansion card
Alula RE934ZT にも: クイック・スタート・マニュアル (4 ページ)
With the translator, sensors are enrolled into the panel via RF transmission. Once
enrolled, the zones are configured in the panel the same way as Connect+ zones. It is
important to follow enrollment instructions carefully, and execute the steps in order, so
that devices are enrolled properly. Before enrollment, the panel will first need to be
set to the proper translator protocol and save the panel settings. This is set via the
dealer portal or installer app.
Enrolling GE Devices
•
Place panel in sensor enrollment mode.
•
Activate particular GE sensor as follows:
o DWS: Open the cover of the sensor
o PIR & Glass break: Open the cover of the sensor
o Key fobs: Press the Lock and Unlock buttons simultaneously for 3 seconds
o Panic: Press the panic button
Enrolling DSC Devices
•
Place panel in sensor enrollment mode.
•
Activate particular DSC sensor as follows:
o DWS: Open and close the cover of the sensor
o PIR & Glass break: Open and close the cover of the sensor
o Key fobs: Press the panic button (lower right)
o Panic: Press the panic button
Enrolling Honeywell Devices
•
Remove batteries on all PIR motion detectors.
•
Place panel in sensor enrollment mode.
•
NOTE: Honeywell sensor types must be enrolled in the following order.
Activate particular Honeywell sensor as follows:
o PIR with Tamper: Press and hold tamper button and insert battery
o PIR without Tamper: Insert battery
o DWS: Cycle the door or window contact three times, either open-close-open or close-open-
close. Allow no more than 3 seconds between actions
o Key fobs: Press the ON (Arm) button; wait two seconds, press the OFF (Disarm) button
o Panic: Open panic and remove the battery. Press and hold the panic button and insert
battery with button pressed. Release button within 3 seconds
Enrolling Napco Devices
Place panel in sensor enrollment mode.
Activate particular Napco sensor as follows:
DWS: Open and close the cover of the sensor
◦
PIR & Glass break: Open and close the cover of the sensor
◦
Key fobs: Press the Aux2 (Panic) button
◦
Panic: Napco Panic is not supported by the translator
◦
Enrolling 2GIG Devices
47-0052-00_Rev A00 Tech Support Line: (888) 88-ALULA (888) 882-5852
RE934ZT_Translator and Z Wave Expansion Card
alula.net