▶ Please check the following items before requesting repair.
Symptoms
The handpiece is getting hot.
The ultrasonic vibration
has stopped.
Checklist
Have you been using the
product for a long time?
Are you applying excessive force
to the blade?
Is the blade or blade fixture
firmly fixed?
Is the blade, the blade fixture,
and the inside tip of the oscillator
contaminated?
Are you applying excessive force to
the operating button?
Was there a beep sound?
(Refer to page �)
Before requesting A/S
If you are cutting hard or thick
materials, heat can be generated
quickly, and it will automatically
switch to standby mode after
one beep sound.
This product is a simple ultrasonic
cutting machine for work. Hold it
correctly and do not apply excessive
force during use.
If the blade is not firmly fixed,
a lot of heat loss can occur, which can
reduce the lifespan of the product.
Clean the inner surface of the
oscillator where the blade fixture is
inserted with a cotton swab.
Release the force and try again.
If you try to cut hard materials by
applying excessive force, there will be
a beep sound and the handpiece will
stop working.
It is in a high-temperature stop state.
Please wait until the handpiece
temperature cools down and then
try again. (Wait for about � minutes
for it to cool down.)
The protective function has been
activated. Turn off the power button,
check the condition of the blade
fixture, and turn on the power again.
Check if the set screw is tightly
fastened. If the blade is heavily
contaminated, replace it with a new
one. Check if the blade fixture is
broken.
Solution
P. ��