- ページ 2

温度コントローラー AKO 14641のPDF 使用方法をオンラインで閲覧またはダウンロードできます。AKO 14641 2 ページ。 Surface temperature controller with 4 relays and 3 probes

AKO 14641 使用方法
CURRENT
PASSWORD
TEMPERATURE
IF PROGRAMMED
SIMULTEANOUSLY
10 Sec.
IF L5=0
PASSWORD
ENTER
DISPLAY
REQUEST
PASSWORD
PASSWORD
Level 2
Parameters
- In the desired menu of LEVEL 1 MENUS,
press
key. LEVEL 2 PARAMETERS
programming is accessed. The first para-
meter of the selected menu is displayed
on the screen.
- Press
key to access the next parame-
ter and
key to return to the previous
one.
- Pressing
key, the controller returns to
the LEVEL 1 MENUS
REMARK: If no key is pressed for 25 seconds in either of the previous steps, the controller
will automatically return to the CURRENT TEMPERATURE display status without modifying
any of the parameters values.
6- Description of parameters and messages
Values in the Def. column are factory-set.
Level 1
Menus and description
rE
Level 2
Control
Level 3
Description
SP
Set Point temperature
C0
Sensor 1 calibration (Offset)
C1
Sensor 1 differential (Hysteresis)
Set Point upper limit
C2
(It cannot be set above this value)
Set Point lower limit
C3
(It cannot be set below this value)
Relay protection delay type:
C4
0=OFF/ON (From the last switch-off)
Protection delay time
C5
(Value for the option selected in parameter C4)
Relay time in ON in case of faulty sensor
C7
(If C7=0 and C8= / 0, the relay will always be OFF disconnected)
Relay time in OFF in case of faulty sensor
C8
(If C8=0 and C7= / 0, the relay will always be ON connected)
C9
Continuous cycle duration
C10 Compressor stops when opening door?
dEF Level 2
DEFROST control
Level 3
Description
d0
Defrost frequency (Elapsed time between 2 starts)
d1
Defrost maximum duration
Type of message during defrost:
(0=Current temperature display)
d2
(1=Defrost start temperature display)
(2=Display dEF message)
Message maximum duration
d3
(Time added at the end of defrost)
d4
Defrost final temperature by sensor 2
Defrost start-up on equipment switch-on:
d5
(0 = No, first defrost according to d0)
(1 = Yes, first defrost according to d6)
d6
Defrost start-up delay on equipment switch-on
Defrost type:
d7
(0=Electrical heater)
(1=Hot gas by-pass)
Time calculation between defrost periods:
d8
(0 = Total real time)
(1 = Compressor operation sum)
Drip time, compressor stops and FAN
d9
relay off when defrost ends
FAn Level 2
FANS control (Evaporator)
Level 3
Description
Fans stop temperature by sensor 2
F0
If sensor 2 is programmed in P4
F1
Sensor 2 differential
F2
Stop fans, when compressor stops?
Fans status during defrost
F3
(0 = Off) (1 = On)
Start-up delay after defrost
F4
Operates if it is higher than d9
F5
Stop fans if the door opens?
AL
Level 2
ALARM control (Visual)
Level 3
Description
Configuration of temperature alarms
A0
(0=Relative to SP) (1=Absolute)
(If A0=0, A1 and A2 range from 0 to 50 ºC/ºF)
A1
Maximum alarm in sensor 1
A2
Minimum alarm in sensor 1
Temperature alarm delay in the start-up
A3
(If programmed in A1, A2)
Temperature alarm delay from
A4
the end of a defrost
Av. Roquetes, 30-38 | 08812 Sant Pere de Ribes | Barcelona | España
Tel. (34) 938 142 700 | Fax (34) 938 934 054 | e-mail: [email protected] |
Apartado (P.O. Box), 5 | 08800 Vilanova i la Geltrú | Barcelona | España
LEVEL 1
LEVEL 2
LEVEL 3
VALUES
MENUS
PARAMETERS
CURRENT
VALUE
EXIT TO
LEVEL 2
EXIT
EXIT TO
PROGRAMMING
LEVEL 1
Level 3
Values
- To DISPLAY the CURRENT VALUE of any
parameter, select the required one and
press
key. Once it is displayed, you
can CHANGE VALUE, pressing
key.
- Press
key to ACCEPT THE NEW. The
programming returns to LEVEL 2 PARA-
METERS.
- Pressing
key, the controller returns to
the LEVEL 2 PARAMETERS
Values Min. Def. Max.
(ºC/ºF) -58.0 0.0
(ºC/ºF) -20.0 0.0 20.0
(ºC/ºF) 0.1
(ºC/ºF)
C3
(ºC/ºF) -58.0 -50.0 C2
0
1=ON (At switch-on)
(min.)
0
(min.)
0
(min.)
0
(h.)
1
(0 = No)
(1 = Yes)
0
Values Min. Def. Max.
(h.)
0
(min.)
0
0
(min.)
0
(ºC/ºF) -58.0 8.0
0
(min.)
0
0
0
(min.)
0
Values Min. Def. Max.
(ºC/ºF) -58.0 4.0
(ºC/ºF) 0.1
(0=No)
(1=Yes)
0
0
(min.)
0
(0 = No)
(1 = Yes)
0
Values Min. Def. Max.
0
(ºC/ºF)
A2
(ºC/ºF) -58.0 0.0
(min.)
0
(min.)
0
Temperature alarm delay from the
A5
moment at which they should operate due to temperature
Temperature alarm delay from digital input disabling
A6
If programmed as "Door contact"
Temperature alarm delay from digital input enabling
A7
If programmed as "Door contact"
A8
Signals if defrost ends due to maximum time
A10 Differential Alarms Temperature A1 and A2
InP
Level 2
Level 3
Digital Input Nº1 configuration
NEW
i1C (0=Disabled) (1=Door Contact) (2=External alarm)
VALUE
(3=Severe external alarm) (4=Remote defrost)
(5=Change of set point iS1 + it1) (6=Low Pressure Input)
i1d Alarm delay of digital Input Nº 1
Polarity of digital input Nº1
i1P (0=Activated on closing contact) (1=Activated on opening contact)
Digital Input Nº2 configuration
i2C (0=Disabled) (1=Door Contact) (2=External alarm)
(3=Severe external alarm) (4=Remote defrost)
(5=Change of set point iS1 + it1) (6=Low Pressure Input)
i2d Alarm delay of digital Input Nº 2
Polarity of digital input Nº2
i2P (0=Activated on closing contact) (1=Activated on opening contact)
iS1 Value of auxiliary set point 1 of "COOL" Relay (Compressor)
it1
Duration of auxiliary set point 1
rAU Level 2
Level 3
Auxiliary relay function (AUX) (0=Alarm) (1=Enabled by key )
CAU (2=Pump down) (3=Second defrost)
tPD Pump down duration
or
dPD Pump down connection delay
60
CnF Level 2
Level 3
P1
Delay of all functions on power supply switch on
Allocation of password to Set Point:
P2
(0=Without allocation)
P3
Initial parameters: (1=YES, configure to "Def" and exit programming)
Connected sensors (1 =Sensor 1) (2 =Sensor 1 + Sensor 2)
P4
(3= Sensor 1 + Sensor 2 + Sensor 3)
P5
Address for units with communication
Temperature display mode: (0=Integers in ºC)
P7
(1=One decimal in ºC) (2=Integers in ºF) (3=One decimal in ºF)
P8
Sensor to be displayed
tid
Level 2
Level 3
L5
Access password to parameters and information
L6
Parameters transfer: (0=Disabled)
PU
Program version (Information)
REMARK: When time parameters are modified, the new values are applied when the current
cycle is completed. In order for it to have an immediate effect, switch the controller off and
211
then on again.
1.0 20.0
MESSAGES
99.9 211
Password request to enter programming parameters
PA
or SET POINT
It indicates defrosting is being carried out. In order to display "dEF" during defrosting,
dEF
it is essential that parameter d2 is set to option 2.
0
1
AE
Flashing with temperature - External alarm
AES Flashing with temperature - Severe external alarm
0
255
Flashing with temperature -Maximum temperature alarm.
AHt
Sensor 1 temperature exceeds the parameter programmed in A1.
10
255
Flashing with temperature - Minimum temperature alarm.
ALt
Sensor 1 temperature is lower than the parameter programmed in A2.
5
255
ALP Flashing with temperature - Error in low pressure switch with compressor in operation.
1
24
oFF Unit off - STANDBY Mode (equipment maintains electric power supply)
0
1
CPY Parameters received from the parameters server.
Pb1 Displays probe 1
Pb2 Displays probe 2
6
120
E1
Sensor 1 failure (Open circuit, crossed, temp.> 105ºC or temp.<-55ºC)
30
255
E2
Sensor 2 failure (Open circuit, crossed, temp.> 105ºC or temp.<-55ºC)
E3
Sensor 3 failure (Open circuit, crossed, temp.> 105ºC or temp.<-55ºC)
ES
Incorrect sensor configuration (See P4, P8)
2
2
EE
Memory failure
5
255
7- Parameters transfer
211
Portable server
0
1
AKO-14918 portable server, with no power
supply, in which parameters programmed in a
0
255
powered controller can be copied by transfer.
0
1
Parameters can be transferred again from the
server to other identical powered controllers.
0
1
Storage dump or fast copy of the para-
meters entered in the portable server
1
255
to the controller:
Press the key
while the controller is being connected to the power supply until the dis-
play shows CPY, indicating that the transfer was made correctly. Disconnect the controller
and reconnect it to the power supply.
211
Storage dump can also be done from parameter L6=2.
1.0 20.0
0
1
8- Maintenance
0
1
Clean the controller surface with a soft cloth, soap and water. Do not use abrasive deter-
3
255
gents, petrol, alcohol or solvents.
0
1
9- Warnings
0
1
The use of the unit without observing the manufacturer's instructions may alter its safety
0.0
211
qualification.
A1
To ensure correct operation of the apparatus, only NTC type probes supplied by AKO should
be used.
0
255
Between -40 ºC and +20 ºC, when the NTC probe is extended up to 1.000 m with minimum
0
255
0,5 mm
2
cable, deviation will be less than 0.25 ºC (Probe extension cable ref. AKO-15586).
AKO ELECTROMECÀNICA, S.A.L.
www.ako.com
Nos reservamos el derecho de suministrar materiales que pudieran diferir levemente de los
descritos en nuestras Hojas Técnicas. Información actualizada en nuestra web: www.ako.com.
(0=No) (1=Yes)
DIGITAL INPUTS
Description
Values Min. Def. Max.
AUXILIARY RELAY control (AUX)
Description
Values Min. Def. Max.
GENERAL STATUS
Description
Values Min. Def. Max.
(1=With allocation of L5 password)
(1=Sensor 1) (2=Sensor 2) (3=Sensor 3)
ACCESS AND INFORMATION control
Description
Values Min. Def. Max.
(1=Send)
(2=Receive)
Transfer
AKO-14918
(min.)
0
30
255
(min.)
0
0
255
(min.)
0
0
255
0
0
1
(ºC/ºF) 0.1
1.0 20.0
0
0
6
(min.)
0
0
255
0
0
1
0
0
6
(min.)
0
0
255
0
0
1
(ºC/ºF) -58.0 0.0
211
(min.)
0
0
255
0
0
3
(min.)
1
10
255
(sec.)
0
5
(min.)
0
0
255
0
0
1
0
0
1
1
2
3
0
0
255
0
1
3
1
1
3
0
0
255
0
0
2
Power supply
Programming