試験装置 dlb AIJGO-22LCDのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。dlb AIJGO-22LCD 16 ページ。 Personal grounding tester with lcd display and dual foot electrode
Wall version
Retool the red switch on the bottom of the
tester to the desired position, if necessary, to
set the measurement resistance limit of the
footwear system.
1.
However, after setting a different limit from the
one used previously, the device must be restarted
for the change to take effect.
2.
Screw the mounting plate to the wall
Fix the tester to the universal holder with
3.
screws in the direction shown in the picture
Connect the wires of the dual foot electrode
4.
and the relays using the 8-pin connector and
also the adapter
Slide the tester with the holder onto the
5.
mounting plate
Remove the protecion foil from the foot
6.
electrode plates
10