温度コントローラー AKO AKO-D14125のPDF 取付説明書をオンラインで閲覧またはダウンロードできます。AKO AKO-D14125 6 ページ。
D141H232 Ed.03
GB
Installation instructions
AKO-D14120 AKO-D14123
AKO-D14023 AKO-D14023-C AKO-D14024
AKO-D14124 AKO-D14125
3- Wiring
The probe and its cable should NEVER be installed in the same conduit as power, control or supply cables.
AKO-D14123, AKO-D14124, AKO-D14125
I max.:
Mode: HEAT
16 A
16 A
L N
(P0=1)
1
2
3
4
5
6
230 V~
50/60 Hz
Probe 1
RES.
AKO-D14023, AKO-D14024
1
2
3
4
5
6
230 V~
50/60 Hz
Probe 1
4- Operation
3 key equipment
Display
Program Mode
COOL relay ON (P0=0)
SET
Standby
RES relay active (P0=1)
mode
SET key
Press for 5 seconds to modify the set point (SP).
Press for 10 seconds to go to the programming menu.
In the programming menu, go to the level displayed or accept
the new value while setting a parameter.
N
H
Up key
/
Pressing for 5 seconds starts/stops defrosting.
In programming menu, allows you to scroll through the
various levels or, during the setting of a parameter, to change
the value.
Q
m
Down key
/
Pressing for 5 seconds activates Standby mode, pressing for 2
seconds returns the equipment to normal mode. In Standby
mode, the equipment performs no actions and only the m
indicator is displayed on the screen.
In programming menu, allows you to scroll through the
various levels or, during the setting of a parameter, to change
the value.
1- Warnings
-Using the equipment without following the manufacturer's
instructions may affect the device's safety requirements. To ensure
that the device operates correctly, only probes supplied by AKO
should be used.
-The unit must be installed in a location protected from vibrations,
water and corrosive gases, where the ambient temperature does
not exceed that shown in the technical data.
-To ensure a correct reading, the probe must be situated in a location
without any external heat influences except for the temperature
which is being measured or controlled.
-The power supply circuit must be provided with a main switch rated
at at least 2 A, 230 V, located close to the equipment. The cables will
enter through the back and should be type H05VV-F or H05V-K.
-The gauge will depend on local regulations, but should in no case be
2
less than 1 mm .
-Connecting wires for the relay contacts should be sized 2.5 mm .
-Between -40 ºC and +20 ºC, if the probe NTC is prolonged till 1.000 m
with a mínimum of cable 0,5 mm², the maximum deviation will be of
0,25 ºC (extension cable for probe ref. AKO-15586)
AKO-D14012
NOTE: Equipment not compatible with AKO-14917 (external
communication module) and AKO-14918 (programming key)
Mode: COLD
16 A
(P0=0)
1
2
3
4
5
6
230 V~
50/60 Hz
Probe 1
COOL
AKO-D14012
1
2
3
4
5
6
_ ~
12 V
Probe 1
_ ~
24 V
1 key equipment
Program Mode
Keyboard
Standby
mode
m
SET key /
Pressing for 5 seconds activates Standby mode, pressing for 2
seconds returns the equipment to normal mode. In Standby mode,
the equipment performs no actions and only the m indicator is
displayed on the screen.
Pressing for 10 seconds goes to the programming menu.
Pressing for 5 seconds in the programming menu goes to the level
displayed on the screen or, during the setting of a parameter, accepts
the new value.
In the programming menu, a short press allows you to scroll
through the various levels or, during the setting of a parameter, to
increment the value. When upper limit is reached, it will start
again from the lower limit.
5- Start-up
(Only 3 key models)
On power-up, the equipment will start up in Wizard mode (P3 / 1
flashing), press N or Q to select the most appropriate
application and press SET.
1: Multipurpose
4: Fresh fish
7: AC
The wizard will configure the parameters of the equipment for the
chosen application (see table "Default settings by application").
I max.:
16 A
Mode: HEAT
16 A
L N
(P0=1)
1
2
120 V~
50/60 Hz
Modbus
AKO-D14023-C
12
13
14
15
1
2
3
4
5
90-260 V~
50/60 Hz
Probe 1
Display
SET
SET key / m
2: Frozen
3: Fruits and vegetables
5: Soft Drinks
6: Bottle racks
8: Heat / Incubators
2- Installation
2
AKO-D14120
I max.:
Mode: COLD
16 A
L N
(P0=0)
3
4
5
6
120 V~
50/60 Hz
Probe 1
RES.
6
7
8
9
10 11
5.1- Access to set point and programming
3 key equipment
5 sec.
Temperature
Release SET
Indication
the set point
1 key equipment
5 sec.
SET
Temperature
Release SET
Indication
7 1 m m
I max.:
16 A
16 A
L N
1
2
3
4
5
6
Probe 1
COOL
10 sec.
t
Release SET
to access
to access
programming
10 sec.
t
Release SET
to go to
to access
Stand-by
programming