- ページ 4
照明器具 ALUZ A1-ZUCO-PVT-BIOSのPDF マニュアルをオンラインで閲覧またはダウンロードできます。ALUZ A1-ZUCO-PVT-BIOS 11 ページ。 Surface zuco pivot bios illuminated
DRY LOCATION APPLICATIONS
1
Measure area where luminaire will be installed. Use a laser line to
create a reference line along installation area, ensuring consistent
alignment of mounting clips. Mark location where each mounting
clip will be installed along reference line.
2
Use 1 mounting clip every 2', rounded up. Use a minimum of 2
mounting clips per fi xture segment. For vertical applications, create
a stopper at the bottom of the run to prevent sliding.
3
Use a mounting clip at the junction between two fi xture segments.
Example: 20' Run.
8'
3" Gap
Mounting Clip
4
Lay mounting clips along reference line and pre-drill using an
appropriate drill bit for surface material and screw size.
Typical screw size is 8/32 x 1".
Note: Allow 1/4" clearance on each side of mounting clip due to
lateral expansion. Only install mounting clips on flat, even surfaces.
5
Screw mounting clips to surface, then snap fi xture into mounting clips.
a
Screw MC-1 to surface, then snap luminaire into mounting clips.
b
Screw MC-2 to surface, then snap luminaire into mounting clips.
c
Screw MC-3 to surface, then snap luminaire into mounting clips.
d
Screw MC-4 to surface, then snap luminaire into mounting clips.
1170 N Red Gum St, Anaheim, CA 92806
aluz.lighting
© ALUZ All Rights Reserved. ALUZ reserves the right to make changes or withdraw specifi cations without prior notice.
A1 Series | Surface
ZUCO Pivot BIOS Illuminated
(A1-ZUCO-PVT-BIOS)
20'
8'
4'
Junction between luminaire segments
866.ALUZ.LTG | 714.535.7900
WET LOCATION APPLICATIONS
1
Measure area where luminaire will be installed. Use a laser line to
create a reference line along installation area, ensuring consistent
alignment of mounting clips. Mark location where each mounting
clip will be installed along reference line.
2
Use 1 mounting clip every 2', rounded up. Use a minimum of 2
mounting clips per fi xture segment. For vertical applications, create
a stopper at the bottom of the run to prevent sliding.
3
Space mounting clips evenly throughout the run.
Example: 20' Run.
8'
3" Gap
Mounting Clip
MC-1 ASSEMBLED DIMENSIONS
1.39"
1.14"
.99"
Clear Lens (CL)
Optic Lens
50% Semi-Frosted Lens (SF)
(15D, 30D, 45D, 60D)
100% Frosted Lens (F)
MC-2 ASSEMBLED DIMENSIONS
1.89"
1.21"
1.06"
Clear Lens (CL)
Optic Lens
50% Semi-Frosted Lens (SF)
(15D, 30D, 45D, 60D)
100% Frosted Lens (F)
MC-3 ASSEMBLED DIMENSIONS
1.39"
2.26"
2.11"
1.50"
Clear Lens (CL)
Optic Lens
50% Semi-Frosted Lens (SF)
(15D, 30D, 45D, 60D)
100% Frosted Lens (F)
MC-4 ASSEMBLED DIMENSIONS
X
1.21"
1.06"
1.45"
Clear Lens (CL)
Optic Lens
50% Semi-Frosted Lens (SF)
(15D, 30D, 45D, 60D)
100% Frosted Lens (F)
Mounting Clips
20'
8'
4'
Junction between luminaire segments
1.39"
1.39"
1.14"
Asymmetric Lens
(ASM)
1.89"
1.89"
1.21"
Asymmetric Lens
(ASM)
1.39"
1.39"
2.26"
1.50"
1.50"
Asymmetric Lens
(ASM)
X
X
1.21"
1.45"
Asymmetric Lens
(ASM)
Installation Instructions
8 / 9 / 2023 / Rev 0
Page 4 of 11
1.45"