- ページ 17
改札口 Alvarado Supervisor 500のPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Alvarado Supervisor 500 19 ページ。 Barrier-free optical counting turnstile
Maintenance
Preventative maintenance should be performed periodically after installation to ensure the product maintains its visual exterior and
optimal performance. To maintain the SU500, follow the instructions below as needed. Due to the various types of exterior finishes
on the SU500, different types of care must be taken to keep the unit clean and undamaged.
Cleaning the Cabinet Exterior
Regular cleaning is the best way to maintain any stainless steel or finished equipment and prevent corrosion.
1.
Stainless steel surfaces may be cleaned using any commercially available stainless steel cleaner or polish. If a heavier scratch
mark is apparent, a metal blend and finish pad by 3M Company or equivalent may be used followed by a stainless steel
cleaner. ALWAYS POLISH IN THE DIRECTION OF THE GRAIN.
2.
Powder-coated cabinet surfaces may be cleaned using a soft damp cloth. Any deep scratches in this type of finish should be
touched up to prevent rust or corrosion from forming. If left untreated, rust can spread under the powder-coat finish.
Cleaning the Top Lid and Sensor Lens Covers
Use cleaning products that are specifically recommended for use on acrylic surfaces. We recommend two products:
•
Brillianize
•
Novus #1
The two recommended products will clean the material and leave a greaseless shine that will repel dust and resist fingerprints. DO
NOT use scouring compounds or chemical cleaners like Windex that contain ammonia or alcohol.
1.
Using a soft cloth, clean the acrylic surfaces according to the instructions provided with the recommended cleaning product.
DO NOT SCRUB THE ACRYLIC!
2.
Check for cracks or scratches on the acrylic sensor lens covers. Sensor lens covers should only be replaced if they are
inhibiting the function of the unit.
Interior Maintenance
Internal Maintenance should occur once every year. Dust build up is the most important concern inside the cabinet. Use canned air
dust remover to clean out all the dust from the inside of the cabinet and specific areas noted below.
1.
Printed Circuit Boards (PCBs): Using canned air dust remover, blow out the dust on the printed control boards.
2.
Sensors: Using canned air dust remover, clean the dust from the optical sensors.
Page 32
For Assistance: [email protected] +1 (909) 591-8431
SU500 Installation Instructions
SU500 Installation Instructions
Weekly Safety Check
Perform the following safety check on a weekly basis to ensure that the turnstile is ready for user operation. If the turnstile does
not pass the Activation , do not use the turnstile. Contact your service professional or Alvarado for assistance.
1.
2.
3.
Troubleshooting
This basic troubleshooting section is provided to aid installers with the most commonly encountered installation problems. If you
require more troubleshooting assistance, contact Alvarado technical support.
Symptom
Unit will not power
up
Blocked Sensor
Auditory Alarms
sounds after 15
seconds (default)
PUD1456R5-0
PUD1R5-0
Attachment - Verify that the cabinet lids and side panels are secure. If necessary, tighten screws.
Passageway - Check the turnstile passageway and entry and exit areas for trash or other debris that may impede traffic or be
a safety hazard.
Count Test - Activate the turnstile and complete a passage in both the entry and exit directions.
Possible Cause
Solution
No Power
Make sure that there is power to the turnstile power terminal block. Check if LEDs are
lit on the main turnstile controller.
Blown Fuse
Check fuse. If necessary replace with a
Bad Power
Meter the 5V (red) and 12V (yellow) output on the power supply supply output. Replace
Supply
power supply if defective.
Wire or cable
Check for a stray wire or cable in front of the transmit and receive operational sensors
blocking sensors
(horizontal arrays).Tuck any stray wire or cable out of sensor viewing area.
For Assistance: [email protected] +1 (909) 591-8431
2.5A (slo-blo) fuse.
Page 33