MSG Installation and Maintenance Instructions
Magnetic / Electric Strike Lock Wiring (Cont.)
Power Supply Specifications
Input:
120VAC, 60Hz, 17W
Output:
+12VDC, 1.0A
The power supply is to be installed near the gate location. Ensure power supply enclosure is weatherproofed.
Wiring Instructions
WARNING
1. Pull 18 gauge cable through the conduit (if used) from the power supply and switch location to the wire access
hole located at the top corner of the gate door on the push side of the gate frame post. [Figure 6]
2. Identify the wiring diagram appropriate for your locking device on Wiring Instructions (Cont.).
Refer to Figure 7 for Magnetic Lock / Fail Safe Electric Strike wiring diagram and Figure 8 for Fail Lock Electric
Strike wiring diagram.
3. At the gate, connect the POSITIVE (+) RED wire coming out of the lock device to the common terminal of the
device providing the sustained activation signal (access switch, push button, etc.) Connect the NEGATIVE (-)
BLACK wiring coming out of the lock device to the NEGATIVE (-) BLACK power supply lead wire.
4. Connect the POSITIVE (+) BLACK/WHITE DASHED STRIPE wire coming out of the power supply to the
appropriate terminal of the device providing the sustained activation signal (access switch, push button, etc.).
5. Plug the power supply into appropriate power source. For both Fail Lock and Fail Safe units, the gate should
lock when power is supplied (if wired correctly). Press and hold the gate activation button: if the gate is functioning
correctly, the lock will release and the gate will unlock.
PUD1201R5-0
120V
Ensure primary power to the unit is off before any wire connections are made.
For Assistance: [email protected] +1 (909) 591-8431
220V
Input:
220VAC, 50Hz, 20W
Output:
+12VDC, 1.25A