Setting Up
IMPORTANT
Power Requirements
• POE+ is only required if the IntraQ-X devices will supply power to door strikes. However, Alvarado
recommends POE+ for all installations, even if the IntraQ-X devices will not power the door strikes.
• Alvarado recommends that the POE+ switch power settings are set to MAX power setting and not Auto-
Negotiate.
• An IntraQ-X can provide a maximum of 12V DC at 600 milliamps to the door strike.
Door Lock/Strike Wiring
The IntraQ-X has a 12V DC relay on the board that can power and activate a door strike. The relay on the board
can be set to normally open or normally closed in the device's configuration. If the door strike is being powered
externally, then the board must connect to an external 12V DC relay. Refer to the diagrams below.
Page 4
The items in this section must be addressed before you attempt to install the IntraQ-X
device.
Relay terminal block
For Assistance: [email protected] +1 (909) 591-8431
IntraQ-X Installtion Guide Version 2.0
IntraQ-X Installtion Guide Version 2.0
PUD3677R1-1