Component Testing Procedures

To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires it.
Illustration
Thermal Cutout
Diode Assembly
Triac
MT2
MT1
GA TE
Capacitor Doubler
Snubber Assembly
Magnetron
Blower Motor
Antenna motor
Wire Harness
16500038
Component
Disconnect all wires from TCO.
Measure resistance across terminals.
Cavity Thermal Fuse ...................................
Magnetron TCO ...........................................
Discharge Capacitors
Remove diode lead from capacitor and
connect ohmmeter.
Reverse leads for second test.
Disconnect wires to triac.
Measure resistance from:
MT1 to MT2 .................................................
MT1 to Gate ................................................
MT2 to Gate ................................................
All terminals to ground .................................
Discharge Capacitors
Remove wires from capacitor terminals and
connect ohmmeter, set on highest
resistance scale to terminals.
Also check between each terminal and
capacitor case.
Disconnect wires to snubber.
Measure resistance across terminals............. Infinite.
Discharge Capacitors
Remove wires from magnetron and connect
ohmmeter to terminals. Also check
between each terminal and ground.
Remove all wires from motor.
Measure resistance across coil ....................... Approximately 30 Ω.
Remove all wires from motor.
Measure resistance across terminals.............. Approximately 3.4 KΩ.
Test continuity of wires ................................... Continuity.
Testing
Open at 219° F (104° C).
Open at 280° F (138° C) and
Infinite resistance in one direction
and 50KΩ or more in the opposite
direction.
NOTE: Analog meter must contain a
battery of 6 volts minimum.
Caution - Do not operate oven with
wire to terminal MT2 removed.
Infinite.
Approximately 40 Ω or more.
Infinite.
Infinite.
Between Terminals: Meter should
momentarily deflect towards zero
then return to over 5 MΩ. If no
deflection occurs, or if continuous
deflection occurs, replace capacitor.
Terminal to Case: Infinite
resistance.
Between Terminals: Less than 1 Ω.
Each terminal to ground measures
Infinite resistance.
NOTE: This test is not conclusive. If
oven does not heat and all other
components test good replace the
magnetron and retest.
2
Results
closed at 180° F (82° C).