計測機器 AKO AKO-59720のPDF 使用方法をオンラインで閲覧またはダウンロードできます。AKO AKO-59720 2 ページ。
5972H002 Ed. 01
Instructions
AKO-59720
Cautions
-If the device is used without following the manufacturer's instructions, it may fail to meet its safety requirements. Only probes supplied by AKO should be used for the device to
operate correctly.
-The equipment should be installed in a place that is protected from vibrations, water and corrosive gases, where the ambient temperature does not exceed the value indicated in the technical
specifications.
-For the reading to be correct, the probe should be placed somewhere without heat sources other than the temperature to be measured or monitored.
-Avoid installing the device on metal walls or near devices that may cause radio emissions.
-AKO-59720 devices should NEVER be operated without installing the external antenna.
-This device must be installed in a place where it will remain at least 20 cm from any human body, to ensure that it complies with the requirements for human exposure to electromagnetic fields.
-This device is powered by a non-rechargeable battery; if it runs out it must be replaced with the AKO-58030 model. The spent battery must not be disposed of with house-
hold waste, it must be taken to a designated collection point. NEVER attempt to recharge the battery, puncture or strike the battery or immerse it in liquids or
throw the battery into a fire.
Installation
Installation conditions: Install the device away from draughts and condensation. Do not place it near to evaporators, condensers or other items that may produce electromagnetic
noise. If it is installed in a chamber, place it as close as possible to the door. If it is installed inside a cabinet or display case, place it as close as possible to its door.
2
1
x2
Ø 2.8 mm
Blue S1 probe (0.8 m)
Red S2 probe (0.8 m)
Black S3 probe (5 m)
Digital Input (0.8 m)
4
Description
en
Temperature monitor with built-in NB-IoT communication. It records the temperature data from the various inputs and the status of
the digital input and transmits it to the cloud (akonet.cloud). Both the configuration and monitoring of the data are carried out in the
cloud itself.
Display and analysis of the logged data
The logged data must be viewed and the device must be configured in the akonet.cloud portal.
The portal allows you to analyse the stored data using graphs, statistics and operating indicators. For more information visit akonet.
cloud.
Simplified declaration of conformity
AKO Electromecánica S.A.L. hereby declares that the AKO-59720 radio equipment (temperature monitor) complies with Directive
2014/53/EU.
The full text of the EU conformity declaration is available at the following internet address:
http://help.ako.com/manuales/declaracion-ue-de-conformidad
Option A
Fixed by screws
3
+
x2
Ø 5 mm
If a probe is to be fixed to a metal conduit, use the supplied
cable ties to secure the probes, 2 cable ties for each probe.
Secure them tightly using pliers to pull the end of the cable
ties.
Option B
Fixed by an adhesive
3 6
m m
7 0
m m
3.
2
3.
1
3.
3