AR BLUE CLEAN
Clean with an air jet the head and check the glow plug pos. C. The distance between
the electrodes must be of 3 mm. If the distance must be adjusted, unscrew glow plug
screw pos. E, remove the glow plug, adjust the distance to acheive the 3 mm
distance. Reassemble the glow plug while checking it is fixed correctly. Place the
combustion back in place using the three screws pos. A.
This maintenance operation must be carried our by skilled personnel.
EVERY MONTH O AFTER 200 HOURS OF WORK
Carry out the first topping up of the pump oil.
Clean the combustion pump filter.
Remove the cover.
Near the pump picture 13 pos. A on the
side of the filter symbol, extract the
plastic filter using a 4 mm socked head
screw. Clean the filter with a light air jet
an place it place back. If necessary
replace it.
This maintenance operation must be
carried our by skilled personnel.
18.
COOLING COIL INTERNAL CLEANING
Contact an Authorized Service Centre.
19.
MACHINE DEMOLITION
If you want to junk your machine, please comply to the laws in force in your Country.
The machine is manufactured with parts containing recyclable metals and plastics.