- ページ 4
バッテリーチャージャー Docking Drawer 0290-00031のPDF インストールマニュアルをオンラインで閲覧またはダウンロードできます。Docking Drawer 0290-00031 5 ページ。
Removing the Receptacle Box–
ForasuccessfulDockingDrawerSlimchargingoutletinstallation,itisNOTnecessarytoremovethe
receptacleboxfromthecablemanagementarms.However,ifthereceptacleboxneedstoberemoved,
pleasefollowthesestepstodisconnect/reconnectthereceptacleboxfromthecablemanagementarms.
1.Removethecablearmgroundconnection
insidethereceptacleboxbyremovingthe
greengroundscrewandringterminalas
shown.DO NOTremovethegroundwire
thatgoestothereceptacle.
2.Removethebluewirenutconnectingthe
blackwirefromthecablechaintotheblack
wiregoingtothecircuitbreaker.
3.UseaPhillipsheadscrewdrivertoremovethe
(2)#10screwsfrominsidethereceptaclebox.
Thiswillallowthecablearmbrackettobe
disconnectedfromthereceptaclebox.
DO NOT REMOVE
4. M ountthepowercordbracketinthecorrect
locationonthebackwallbehindthedrawer
asshowninthedrawing.
5.Installthedrawerinthecabinet,andholdon
totheendofthearmassembly.
6.Passthewiresfromthecablemanagement
armsintothereceptacleboxandreattach
thebracketusingthescrewdriverand
(2)#10screws.
7.Securethereceptacleboxtothebackofthe
drawerusingtheinstallersuppliedhardware.
8. R econnecttheblackwirefromthecircuit
breakertotheblackwirefromthecable
managementarmusingthebluewirenut.
9. DO NOT FORGET TO REATTACH THE
GROUND WIRE INSIDE THE RECEPTACLE
BOX. TORQUE SCREW TO 16-18 IN-LBS.
ENSURE THAT THE CIRCUIT BREAKER IS
WIRED IN SERIES WITH THE LINE (BLACK)
WIRE. SEE WIRE DIAGRAM.
MAKE SURE BOTH GROUND SCREWS
ARE SECURELY CONNECTED!
TORQUE TO 16-18 IN-LBS
4