- ページ 5

呼吸器製品 3M 37193のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。3M 37193 6 ページ。 Particulate respirator n95

3. Place respirator on your face so that the foam rests on your nose and the bottom panel is open under chin.
Hold the bottom panel securely under your chin. Pull the top strap over your head and position it high on
the back of the head (3a). Then pull the bottom strap over your head and position it around the neck and
below the ears (3b). Adjust for a comfortable fit by pulling top panel toward the bridge of the nose and
bottom panel under chin.
4. Place your fingertips from both hands at the top of the metal nosepiece. Using two hands, mold the nose
area to the shape of your nose by pushing inward while moving your fingertips down both sides of the
nosepiece.
! Pinching the nosepiece using one hand may result in improper fit and less effective respirator
performance. Use two hands.
5. Perform a User Seal Check prior to each wearing. To check the respirator-to-face seal, cover the middle
panel with one or both hands. For the 9210 respirator, inhale and exhale sharply. For the 9211 respirator,
inhale sharply. Be careful not to disturb the position of the respirator. If air leaks around the nose,
readjust the nosepiece as described in step 4. If air leaks around respirator edges, adjust panels and straps.
If you CANNOT achieve a proper fit, DO NOT enter the contaminated area. See your supervisor.

Removal Instructions

Cup respirator in hand to maintain position on face and pull bottom strap over head. Still holding the
respirator in position, pull top strap over head and remove respirator.

NIOSH Approved: N95

At least 95% filtration efficiency against solid and liquid aerosols that do not contain oil.
5
0515 IS-17011