3. Check all attachments for secureness prior to each use. See User Instructions included with air
regulating valves for further information.
3M™ Dual Airline System
Note: See the Dual Airline User Instructions for complete details on use, cleaning, and maintenance.
To meet the U.S. National Institute for Occupational Safety and Health (NIOSH) requirement for
minimum (4cfm/115 lpm) and maximum (15cfm/424 lpm) airflow, the air control valves approved for use
TM
with the 3M
7000 Series Respirators must be operated within the supply pressure ranges and hose
lengths stated in User Instructions with air regulating valves. Failure to do so may result in sickness or
death.
FITTING INSTRUCTIONS
Must be followed each time respirator is worn.
Donning Respirator
Fig. 13
1. Fully loosen all six headstraps, place facepiece on face and pull head harness to back of head. (Fig.
13)