- ページ 9
水ポンプ Cliq AS-1001DのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Cliq AS-1001D 12 ページ。 Suction pump
Troubleshooting
If you run into problems with the product, refer to the possible causes below to perform simple troubleshooting. If the problem cannot be solved,
send the product to an authorized service center for examination and repair.
Problem
Unit does not start
Reduced performance
No suction
Transportation, Storage, and Disposal
Transportation
• General transportation of the unit should correspond to the conditions outlined in the 'Product Introduction' section of this manual.
• In the event that the AS-1001D suction pump needs to be sent to an authorized service center for inspection and repair, do not package the
collection container, suction tubing, inline filter, intermediate tubing, collection container coaster, or any single-use accessories (such as a
suction catheter) in the shipment.
Storage
Storage of the AS-1001D suction pump should correspond to the conditions outlined in the "Product Introduction" section of this manual.
Disposal
• When the product's life cycle is at an end, all components of the unit must be disposed of in accordance with local regulations.
• Take care that the unit is clean and that the various materials are carefully separated for disposal.
• The European Union (EU) directives 2012/19/EU, known as the WEEE (Waste Electrical and Electronic Equipment) Directive, and 2011/65/EU, referred
to as the RoHS (Restrictions on Hazardous Substances) Directive prohibits the disposal of this device in the domestic waste.
• Outside the EU: Follow disposal regulations in the country of use.
Copyright © 2019 ANEST IWATA SPARMAX Co., Ltd. All rights reserved.
Possible cause
Unit is not plugged into mains
properly.
Mains not supplying power.
The fibrous material inside the
inline filter is wet or damaged.
Wrong voltage and current levels.
Unit over heated.
The fibrous material inside the
inline filter is wet,
or
stained,
damaged.
Tubing is blocked.
Tubing is leaking air.
Connection between inline filter
and inlet is loose.
is damaged.
Collection container
overflowed.
Collection container
The fibrous material inside the
inline filter is wet or damaged.
Suction tubing is blocked.
Remedy
Check plug connection. Make sure plug is properly
inserted into mains.
Check that the mains is live by trying another device.
Replace the inline filter.
Check that the mains provides the voltage and current
levels required by this device.
Please contact qualified service personnel for repair.
Replace the inline filter.
Check if any tubing is blocked. If so, replace tubing.
Make sure that all tubing is securely connected and that there
are no leaks.
Check filter connection. Make sure fiter is tightly
connected to inlet.
Replace collection container.
Empty the collection container.
Replace the inline filter.
Clean or replace suction tubing.
9 / 12
Cliq_AS-1001D Manual (230V50Hz_20190125.1)
3510406D