- ページ 5
パワードライバー ASG BLG-5000 SeriesのPDF 操作マニュアルをオンラインで閲覧またはダウンロードできます。ASG BLG-5000 Series 17 ページ。 With built in screw counter, with built in screw counter and pulse system, for use with screw counter
ASG BLG-5000 Series にも: 操作マニュアル (7 ページ)
BLG-BC2 Features
•
Brushless screwdriver with built-in screw counter and pulse
system
•
Contents: BLG-BC2 Input/Output Cable, Application software,
communication specifications
Pulse System
The pulse system is a mechanism using an electric signal (pulse) that
occurs during motor revolutions. By installing several fasteners into
the assembly the screwdriver learns the numbers of motor revolutions
required to correctly tighten the fasteners to the desired torque. The
driver then establishes the minimum to maximum revolutions for
process acceptance and displays the result of screw tightening with the
LED green and red lights on the unit.
Counter Display Section
4
1
5
6
7
8
Screw Count Display Section/Set Value Display Section
•
In the normal mode, the screw fastening count set
value is displayed first, and after starting the count, the
remaining screw fastening count is displayed. The count
decreases with each screw fastening operation and the
remaining screw fastening count is displayed.
Function Display Section
•
The symbol corresponding to the set item is displayed in
the setting mode.
F1 Button
•
Press and hold the F1 button until the "P" appears then
"ON" is displayed. Continue to press the F1 button to scroll
through the setup functions. Press and hold the F1 button
until the buzzer sounds twice to save the changes.
F2, F3 Button
•
Using these buttons, the set value can be changed in the
function setting. Some set values are limited depending on
the function to be set. Press and hold the F2 button until
[r0] is displayed and the pass/fail lights blink.
Pass Light*
•
When the screw fastening result is "OK", the green LED light
turns ON.
ASG, Division of Jergens, Inc.
S. Waterloo Road | Cleveland, OH
15700
HIOS BLG Series: BLG-BC2
Operational Manual
Function Display
1
2
Section
3
BC2 Input/Output
2
Cable (optional)
Display for screw
3
count and set value
4
F2 Button
5
F1 Button
6
F3 Button
7
Fail Light
8
Pass Light
| Phone: (
44110-3898
888) 486-6163
Fail Light*
•
When the screw fastening result is "NG", the red LED light
turns ON.
Direct Teaching
F1, F2, and F3 Buttons: These are used for each setup.
Display: Number of motor revolutions is displayed and either
Pass/Fail light illuminates. The number of motor revolutions is
displayed up to 3 digits, up to 999.
NOTE: Before Direct Teaching, fasten 1 or 2 screws to adjust the
start position. This is a must.
1. F2 Button: Press and hold until "r 0" is displayed and Fail/Pass
lights blink.
Control Unit
3rd, 2nd, 1st digit
2.
Start Direct Teaching: Fasten 3 or more of the same screws into
the same joint. Direct teaching needs to be done using screws,
parts, and a method of pick up which will be used in your produc-
tion.
3.
F3 Button: Press to select the acceptable range of Pass/Fail crite-
ria. It is displayed in the order of ±0%, ±5%, ±10%, ±15%, ±20%.
4.
F1 Button: Press to confirm the reference values of Pass/Fail in-
cluding the acceptable range. Example: Assuming the reference
values including the acceptable range are from 90 to 120, the
pass range is from 91 to 119.
FAIL
Note: In order to complete Direct Teaching, make sure to work
through all the steps (1-4) .
5. F2 Button: Press and hold until the buzzer sounds twice to
complete Direct Teaching.
| Fax: (
| Email: [email protected] | Web: www.asg-jergens.com
216) 481-4519
PASS
FAIL